|本期目录/Table of Contents|

[1]王丽,等.基于FDS+EVAC的某高校学生宿舍楼火灾疏散能力研究[J].中国安全生产科学技术,2018,14(1):136-142.[doi:10.11731/j.issn.1673-193x.2018.01.022]
 WANG Li,ZENG Jian,REN Changxing.Research on evacuation ability of student dormitory building fire in certain university based on FDS+EVAC[J].JOURNAL OF SAFETY SCIENCE AND TECHNOLOGY,2018,14(1):136-142.[doi:10.11731/j.issn.1673-193x.2018.01.022]
点击复制

基于FDS+EVAC的某高校学生宿舍楼火灾疏散能力研究
分享到:

《中国安全生产科学技术》[ISSN:1673-193X/CN:11-5335/TB]

卷:
14
期数:
2018年1期
页码:
136-142
栏目:
职业安全卫生管理与技术
出版日期:
2018-01-31

文章信息/Info

Title:
Research on evacuation ability of student dormitory building fire in certain university based on FDS+EVAC
文章编号:
1673-193X(2018)-01-0136-07
作者:
王丽1 2 曾坚1任常兴3
(1.天津大学 建筑学院,天津 300072; 2.天津理工大学 环境科学与安全工程学院,天津 300384;3.公安部天津消防研究所,天津 300381)
Author(s):
WANG Li12 ZENG Jian1 REN Changxing3
(1. School of Architecture, Tianjin University, Tianjin 300072, China; 2. School of Environmental Science and Safety Engineering, Tianjin University of Technology, Tianjin 300384, China; 3. Tianjin Fire Research Institute of MPS, Tianjin 300381, China)
关键词:
高校学生宿舍FDS+EVAC火灾疏散能力改进
Keywords:
university student dormitory FDS+EVAC fire evacuation ability improvement
分类号:
X932
DOI:
10.11731/j.issn.1673-193x.2018.01.022
文献标志码:
A
摘要:
针对高校学生宿舍火灾事故频发、人员疏散难的问题,选取某高校南区的一栋标准宿舍楼作为研究对象,根据实际情况,利用FDS+EVAC软件建立几何模型,设置火灾场景及疏散相关参数,模拟宿舍发生火灾时火灾的发生发展过程,以及人员在火灾情景下的疏散行为;对软件模拟结果进行分析研究,得出可用安全疏散时间和必需安全疏散时间,将这2个时间进行对比判断,评价该宿舍楼的安全性能不达标;对比现行的标准规范,认为该宿舍楼不符合安全标准规范的要求,必须采取合理有效措施增加可用安全疏散时间或降低必需安全疏散时间;最后,通过FDS+EVAC模拟结果对比,结合宿舍楼的实际情况,给出合理的整改建议。研究成果可为高校学生宿舍楼的火灾安全性能分析和改进,提供参考和借鉴。
Abstract:
Aiming at the problems of frequent fire accidents and difficult personnel evacuation in the university student dormitory, a standard dormitory building in the southern district of a certain university was selected as the research object. According to the actual situation, a geometric model was established by using FDS+EVAC software, and the relative parameters of fire scene and evacuation were set, then the occurrence and development processes of dormitory fire were simulated, as well as the personnel evacuation behavior in the fire scene. The simulation results were analyzed to obtain the available safe evacuation time (ASET) and the required safe evacuation time (RSET), then the safety performance of the dormitory building was evaluated as disqualification by comparing the ASET and RSET, and the corrective recommendations were put forward by comparing with the current standards and specifications. Finally, some reasonable rectification measures were put forward through comparing the simulation results of FDS+EVAC and considering the actual situation of dormitory building. The results can provide the reference for the analysis and improvement of fire safety performance in the university student dormitory building.

参考文献/References:

[1]李琳, 程远平, 吴蕾,等. 高校学生宿舍消防安全疏散[J]. 消防科学与技术, 2010, 29(2):122-125. LI Lin, CHENG Yuanping,WU Lei,et al. Fire safety evacuation research on college student dormitories [J]. Fire Science and Technology, 2010,29(2): 122-125.
[2]霍然,胡源,李元洲.建筑火灾安全工程导论(第2版)[M].合肥: 中国科学技术大学出版社,2009.
[3]霍然. 性能化建筑防火分析与设计[M]. 合肥:安徽科学技术出版社, 2003.
[4]范维澄, 孙金华, 陆守香. 火灾风险评估方法学[M]. 北京:科学出版社, 2006.
[5]National Institute of Standards and Technology.Fire Dynamics Simulator (Version 5)User’s Guide[EB/OL].(2007-10-01)[2018-01-20].http://fire.nist.gov/bfrlpubs/fire07/PDF/f07053.pdf.
[6]VTT Technical Research Centre of Finland.Fire Dynamics Simulator with Evacuation: FDS+EvacTechnical Reference and User’s Guide[EB/OL].[2018-01-20].https://pdfs.semanticscholar.org/f25c/089e83048beefc756bf17a210f0efff0b8b3.pdf.
[7]钟茂华,火灾过程动力学特性分析[M],北京: 科学出版社,2007.
[8]SHI C L, ZHONG M H, FU T R, et al. An investigation on spill plume temperature of large space building fires[J]. Journal of Loss Prevention in the Process Industries, 2009, 22(1):76-85.
[9]王志刚, 倪照鹏, 王宗存,等. 设计火灾时火灾热释放速率曲线的确定[J]. 安全与环境学报, 2004(S1):50-54. WANG Zhigang, NI Zhaopeng, WANG Zongcun,et al. Determination of heat release rate curve when designing fire [J]. Journal of Safety and Environment, 2004(S1): 50-54.
[10]范维澄.火灾学简明教程[M]. 合肥:中国科学技术大学出版社. 1995.
[11]FRUIN J J. Pedestrian planning and design[J]. Metropolitan Association of Urban Designers & Environmental Planners, 1971.
[12]田玉敏,张伟,马宏伟,等.人群应急疏散[M].北京:化学工业出版社, 2014:16-17.
[13]王辉东. 某宾馆火灾烟气扩散及疏散模拟研究[J]. 中国安全生产科学技术, 2011, 7(12):61-66. WANG Huidong. Study on simulation of smoke spread and evacuation in hotel fire [J]. Journal of Safety Science and Technology, 2011,7(12): 61-66.
[14]中华人民共和国公安部.建筑设计防火规范:GB 50016-2014[S].北京:中国计划出版社,2015.
[15]李树声. 大空间建筑火灾烟气蔓延的数值模拟[D]. 哈尔滨:哈尔滨工程大学, 2006.
[16]TOGAWA K. Study of fire escapes basing on the observations of multiple currents[R]. Tokyo: Building Research Institute, Ministry of Construction, 1995.
[17]潘应久, 陈淑燕. 改进的大型场馆看台区行人疏散时间模型[J]. 东南大学学报(自然科学版), 2017, 47(3):613-618. PAN Yingjiu, CHEN Shuyan.Improved model about pedestrian evacuation time in large-scale stadium audience area [J]. Journal of Southeast University (Natural Science Edition), 2017, 47(3): 613-618.
[18]谢宇. 火灾的防范与自救[M].西安:西安地图出版社, 2010.

相似文献/References:

[1]陈俊敏,姚小林,高宁,等.房间开门形式和走廊转角条件对人员疏散规律 影响的实验研究与数值模拟分析[J].中国安全生产科学技术,2012,8(6):10.
 CHEN Jun min,YAO Xiao lin,GAO Ning,et al.Experimental and numerical simulation study on influences of room door conditions and corridor corner conditions to evacuation rule[J].JOURNAL OF SAFETY SCIENCE AND TECHNOLOGY,2012,8(1):10.
[2]王群,王江川.障碍墙对人员疏散影响的数值模拟研究[J].中国安全生产科学技术,2014,10(1):53.[doi:10.11731/j.issn.1673-193x.2014.01.008]
 WANG Qun,WANG Jiang chuan.Numerical simulation study on effect of obstacle wall to evacuation[J].JOURNAL OF SAFETY SCIENCE AND TECHNOLOGY,2014,10(1):53.[doi:10.11731/j.issn.1673-193x.2014.01.008]

备注/Memo

备注/Memo:
中国博士后科学基金第58批面上项目(2015M581299);天津市自然科学基金项目(17JCQNJC06900);天津市高等学校科技发展基金计划项目(20140526);全国社会科学重点项目(12AZD101)
更新日期/Last Update: 2018-02-12