|本期目录/Table of Contents|

[1]李华,阚双艳,益朋.嵌套式受限空间火灾危险性分析与优化策略研究[J].中国安全生产科学技术,2025,21(10):156-165.[doi:10.11731/j.issn.1673-193x.2025.10.019]
 LI Hua,KAN Shuangyan,YI Peng.Research on fire hazard analysis and optimization strategies for nested confined spaces[J].Journal of Safety Science and Technology,2025,21(10):156-165.[doi:10.11731/j.issn.1673-193x.2025.10.019]
点击复制

嵌套式受限空间火灾危险性分析与优化策略研究

《中国安全生产科学技术》[ISSN:1673-193X/CN:11-5335/TB]

卷:
21
期数:
2025年10期
页码:
156-165
栏目:
职业安全卫生管理与技术
出版日期:
2025-10-30

文章信息/Info

Title:
Research on fire hazard analysis and optimization strategies for nested confined spaces
文章编号:
1673-193X(2025)-10-0156-10
作者:
李华阚双艳益朋
(西安建筑科技大学 资源工程学院,陕西 西安 710055)
Author(s):
LI Hua KAN Shuangyan YI Peng
(School of Resources Engineering,Xi’an University of Architecture and Technology,Xi’an Shaanxi 710055,China)
关键词:
密室逃脱类场所火灾模拟火灾荷载烟气蔓延可用疏散时间
Keywords:
escape room-type venues fire simulation fire load smoke spread available evacuation time
分类号:
X932
DOI:
10.11731/j.issn.1673-193x.2025.10.019
文献标志码:
A
摘要:
为深入探究嵌套式受限空间的消防安全性能化设计优化策略,以调研统计密室逃脱类场所火灾荷载密度数据为基础,并通过建立嵌套式密室场所典型火灾模型,提出房门一键开启决策时间模型,分析房门一键开启时间阈值,进而对比分析不同火灾场景下温度、CO体积分数和能见度变化规律。研究结果表明:中央火源位置房门一键开启的决策时间为7.3 s。通过对比纵向与横向蔓延路径,发现横向蔓延可在100 s时封锁疏散通道,可用疏散时间被显著缩短。喷淋设施改造后,温度峰值下降超过270 ℃,CO体积分数峰值下降超过0.1%,出口位置温度和CO体积分数达到临界值的时间被显著延缓。在温度、CO体积分数和能见度等指标分析基础上,提出高灵敏度感烟探测器与一键开启房门联动装置、喷淋与机械排烟协同系统的优化方案,可用疏散时间增幅达到54%。研究结果可为小尺度嵌套式受限空间的消防措施优化设计提供理论支撑。
Abstract:
In order to deeply explore the optimization strategies for performance-based fire safety design of nested confined spaces,this study is grounded on the investigation and statistics of fire load density data in escape room-type venues.By establishing a typical fire model for nested escape room venues,a decision-time model for one-touch door opening is proposed to analyze the time threshold of one-touch door opening.Furthermore,the variation patterns of temperature,CO volume fraction,and visibility are compared and analyzed under different fire scenarios.The results show that the decision-making time for one-touch door opening when the fire source is centrally located is 7.3 s.By comparing vertical and horizontal fire spread paths,it is found that horizontal spread can block evacuation routes at 100 s,significantly shortening the available evacuation time.After retrofitting the sprinkler system,the peak temperature drops by more than 270 ℃,and the peak CO volume fraction decreases by more than 0.1%.The time for temperature and CO volume fraction at the exit position to reach critical thresholds is significantly delayed.Based on the analysis of indicators such as temperature,CO volume fraction,and visibility,an optimization scheme is proposed that links a high-sensitivity smoke detector with a one-touch door opening device,and integrates a collaborative system of sprinklers and mechanical smoke exhaust.This optimization scheme increases the available evacuation time by 54%.The findings provide theoretical support for the optimal design of fire protection measures in small-scale nested confined spaces.

参考文献/References:

[1]赵学涛.“密室逃脱”场所消防安全风险及防控管理研究[J].中国应急救援,2023(4):35-38. ZHAO Xuetao.Research on fire safety risk,prevention and control management of “secret chamber escape” business[J].China Emergency Rescue,2023,(4):35-38.
[2]HUANG Y F,WANG E S,BIE Y S.Simulation investigation on the smoke spread process in the large-space building with various height[J].Case Studies in Thermal Engineering,2020,18:100594.
[3]邹亚平.装配式地铁车站站厅公共区火灾烟气模拟分析[J].中国安全生产科学技术,2024,20(增刊1):226-231. ZOU Yaping.Simulation analysis of the subway hall fire smoke flow in prefabricated metro station[J],Journal of Safety Science and Technology,2024,20(Supplement 1):226-231.
[4]WU L,HU P,CHENG H H,et al.Full-scale experimental study on the spatial distribution of smoke temperature in multi-room corridor structures inside buildings[J].Journal of Building Engineering,2025,104:112358.
[5]TAO H J,ZHU G Q,XIA Y,et al.Influence of mechanical smoke exhaust on smoke spread in underground tunnel[J].Case Studies in Thermal Engineering,2018,12:47-54.
[6]ZHANG Z Y,YAO X W,XING Z Y,et al.Understanding fire combustion characteristics and available safe egress time in underground metro trains:a simulation approach[J].Chaos,Solitons & Fractals,2024,187:115434.
[7]叶继红,孙浩东.受限空间建筑火灾蔓延影响因素对比试验研究[J].建筑结构学报,2024,45(10):31-41. YE Jihong,SUN Haodong.Comparative experimental study on factors affecting fire spread in enclosed buildings[J].Journal of Building Structures,2024,45(10):31-41.
[8]傅经纬,刁立赛,张英华,等.有限空间密室类娱乐场所火灾蔓延特性研究[J].工业建筑,2024,54(2):90-97. FU Jingwei,DIAO Lisai,ZHANG Yinghua,et al.Research on fire spread characteristics of escape room entertainment venues with spatial complexity[J].Industrial Construction,2024,54(2):90-97.
[9]李华,孙林霞,益朋.多分隔受限场景空间火灾疏散安全性分析[J].中国安全生产科学技术,2024,20(5):107-114. LI Hua,SUN Linxia,YI Peng.Analysis of fire evacuation safety in space with multiple partitioned confined scene[J].Journal of Safety Science and Technology,2024,20(5):107-114.
[10]UGUR D,SERDAR S.Fire load and fire growth characteristics in modern high-rise buildings[J].Fire Safety Journal,2023,135:103710.
[11]DING Y F,CHEUNG W K,ZHANG Y X,et al.Digitized fuel load survey in commercial and university office buildings for fire safety assessment[J].Fire Safety Journal,2024,150:04287.
[12]中华人民共和国应急管理部.建筑火灾荷载调查与统计分析方法:XF/T 1427—2017[S].北京:中国标准出版社,2017.
[13]中华人民共和国公安部.火灾自动报警系统设计规范:GB 50116—2013[S].北京:中国计划出版社,2014.
[14]中华人民共和国住房和城乡建设部.自动喷水灭火系统设计规范:GB 50084—2017[S].北京:中国计划出版社,2018.
[15]邢倩倩,肖梅玲,徐子祺,等.昆明城中村居民楼的火灾应急疏散[J].消防科学与技术,2019,38(7) :942-945. XING Qianqian,XIAO Meiling,XU Ziqi,et al.Fire emergency evacuation of fire in urban residential buildings in Kunming City[J].Fire Science and Technology,2019,38(7):942-945.
[16]KARL F,ENRICO R,DANIEL N,et al.The representation of evacuation movement in smoke-filled underground transportation systems[J].Tunnelling and Underground Space Technology,2019,90:28-41.
[17]中华人民共和国应急管理部.点型感烟火灾探测器:GB 4715—2024[S].北京:中国标准出版社,2024.
[18]全国消防标准化技术委员会建筑消防安全工程分技术委员会.建筑防烟排烟系统技术标准:GB 51251—2017 [S].北京:中国计划出版社,2017.

相似文献/References:

[1]项琴,李远富,朱宏伟.基于安全疏散的高速铁路桥梁救援定点站台设计参数研究[J].中国安全生产科学技术,2016,12(7):168.[doi:10.11731/j.issn.1673-193x.2016.07.030]
 XIANG Qin,LI Yuanfu,ZHU Hongwei.Study on design parameter of rescue site platform on high speed railway bridge based on safety evacuation[J].Journal of Safety Science and Technology,2016,12(10):168.[doi:10.11731/j.issn.1673-193x.2016.07.030]
[2]袁春燕,郑高凯,郎雨佳,等.考虑不同场景的砖木结构古建筑火灾特征研究[J].中国安全生产科学技术,2019,15(10):158.[doi:10.11731/j.issn.1673-193x.2019.10.025]
 YUAN Chunyan,ZHENG Gaokai,LANG Yujia,et al.Study on fire characteristics of ancient buildings with brickwood structure under different fire scenes[J].Journal of Safety Science and Technology,2019,15(10):158.[doi:10.11731/j.issn.1673-193x.2019.10.025]
[3]苏峰,张钧,朱晓平,等.基于FDS的管廊电缆火灾动态风险评估研究*[J].中国安全生产科学技术,2024,20(5):77.[doi:10.11731/j.issn.1673-193x.2024.05.011]
 SU Feng,ZHANG Jun,ZHU Xiaoping,et al.Research on dynamic risk assessment of cable fire inside utility tunnel based on FDS[J].Journal of Safety Science and Technology,2024,20(10):77.[doi:10.11731/j.issn.1673-193x.2024.05.011]
[4]李华,孙林霞,益朋.多分隔受限场景空间火灾疏散安全性分析*[J].中国安全生产科学技术,2024,20(5):107.[doi:10.11731/j.issn.1673-193x.2024.05.015]
 LI Hua,SUN Linxia,YI Peng.Analysis of fire evacuation safety in space with multiple partitioned confined scene[J].Journal of Safety Science and Technology,2024,20(10):107.[doi:10.11731/j.issn.1673-193x.2024.05.015]
[5]周梓晨,智茂永,赵海汇,等.不同气压下民用飞机货舱火灾的数值模拟研究*[J].中国安全生产科学技术,2025,21(8):174.[doi:10.11731/j.issn.1673-193x.2025.08.022]
 ZHOU Zichen,ZHI Maoyong,ZHAO Haihui,et al.Numerical simulation study of civil aircraft cargo compartment fires at different air pressures[J].Journal of Safety Science and Technology,2025,21(10):174.[doi:10.11731/j.issn.1673-193x.2025.08.022]

备注/Memo

备注/Memo:
收稿日期: 2025-07-04
作者简介: 李华,博士,副教授,主要研究方向为企业风险评估与安全管理、公共安全与应急管理。
通信作者: 益朋,硕士,讲师,主要研究方向为安全与应急管理。
更新日期/Last Update: 2025-10-29