|本期目录/Table of Contents|

[1]周洋,卜蓉伟,陈波,等.受限空间开口对细水雾灭火有效性影响实验研究[J].中国安全生产科学技术,2017,13(11):135-142.[doi:10.11731/j.issn.1673-193x.2017.11.022]
 ZHOU Yang,BU Rongwei,CHEN Bo,et al.Experimental study on influence of opening in confined space on suppression effectiveness of water mist[J].JOURNAL OF SAFETY SCIENCE AND TECHNOLOGY,2017,13(11):135-142.[doi:10.11731/j.issn.1673-193x.2017.11.022]
点击复制

受限空间开口对细水雾灭火有效性影响实验研究
分享到:

《中国安全生产科学技术》[ISSN:1673-193X/CN:11-5335/TB]

卷:
13
期数:
2017年11期
页码:
135-142
栏目:
职业安全卫生管理与技术
出版日期:
2017-11-30

文章信息/Info

Title:
Experimental study on influence of opening in confined space on suppression effectiveness of water mist
文章编号:
1673-193X(2017)-11-0135-08
作者:
周洋1卜蓉伟1陈波2张武晖3
(1.中南大学 土木工程学院,长沙 湖南 410075;2.广州中国科学院工业技术研究院,广州 广东 511458;3.庆阳市公安消防支队,甘肃 庆阳,745000)
Author(s):
ZHOU Yang1 BU Rongwei1 CHEN Bo2 ZHANG Wuhui3
(1. School of Civil Engineering, Central South University, Changsha Hunan 410075, China; 2. Institute of Industry Technology, Guangzhou & Chinese Academy of Sciences, Guangzhou Guangdong 511458, China; 3. Qingyang Fire Detachment, Qingyang Gansu 745000, China)
关键词:
细水雾灭火有效性受限空间开口位置开口尺寸
Keywords:
water mist fire suppression effectiveness confined space opening position opening size
分类号:
X936
DOI:
10.11731/j.issn.1673-193x.2017.11.022
文献标志码:
A
摘要:
为了探讨开口的位置与尺寸对受限空间内的细水雾灭火有效性的影响,设计了一个尺寸为1.2 m×1.2 m×1.2 m的特殊受限空间模拟实验台,开展了一系列细水雾灭火对比实验,测量了烟气温度以及灭火时间等实验参数,通过改变实验燃料、火源功率、开口尺寸、开口位置等因素来研究开口对特殊受限空间内细水雾灭火有效性的影响规律。结果表明:在特殊受限空间内,相同条件下,开口位置由下至上,细水雾抑制火灾有效性由低至高;开口尺寸由大至小,细水雾抑制火灾有效性由高至低。当开口尺寸足够小以后,细水雾抑制火灾有效性反而会逐渐增强。
Abstract:
In order to investigate the influence of the position and size of opening in the confined space on the fire suppression effectiveness of water mist, a simulation experimental platform for the specific confined space with the size of 1.2 m×1.2 m×1.2 m was designed. A series of contrastive experiments on the fire suppression by water mist were conducted and some experimental parameters such as smoke layer temperature and fire-extinguishing time were measured, then the influence of opening on the fire suppression effectiveness of water mist in the specific confined space was studied through changing some factors such as the fuel type, the heat release rate of fire source, and the size and position of opening. The results showed that the fire suppression effectiveness of water mist increases with the higher opening position and the bigger opening size under the same experimental conditions in the special confined space. However, the fire suppression effectiveness of water mist increases when the opening size is small enough.

参考文献/References:

[1]G. Grant, J. Brenton, D. Drysdale. Fire suppression by water sprays [J], Progress in Energy and Combustion Science, 2000, 26(2): 79-130.
[2]G. G. Back. An Overview of Water Mist Fire Suppression System Technology [A]. Proceedings of Halon Options Technical Working Conference[C], Albuquerque, NM, 1994: 327.
[3]Meenakshi Gupta, Amit Pasi, Anjan Ray, et al. An experimental study of the effects of water mist characteristics on pool fire suppression[J]. Experimental Thermal and Fluid Science, 2013, 44: 768-778.
[4]A. K. Kim, Z. Liu. Fire suppression performance of water mist under ventilation and cycling discharge conditions [A]. 2nd International Water Mist Conference 2002[C], Amsterdam, Netherlands, 2002: 61-76.
[5]E. A. Ural, R. G. Bill. Fire Suppression Performance Testing of Water Mist Systems for Combustion Turbine Enclosures [A]. Proceedings of Halon Options Technical Working Conference[C], Albuquerque, 1995: 449.
[6]丛北华,廖光煊,刘江虹.细水雾抑制熄灭室内火灾的有效性模拟实验研究[J]. 火灾科学, 2002, 11(3): 152-156. CONG Beihua, LIAO Guangxuan, LIU Jianghong. Experimental Investigation of Suppression Effectiveness of the Fire in a Confined Space with Water Mist[J]. Fire Safety Science, 2002, 11(3): 152-156.
[7]Liu Zhigang and Kim Andrew K, Su Joseph Z. Examination of performance of water mist fire suppression systems under ventilation conditions [J]. Journal of Fire Protection Engineering August 2001, 11(3): 164-193.
[8]Liu Z. G., Kim A. K., Su J. Z. Examination of the extinguishment performance of a water mist system using continuous and cycling discharges [J]. Fire Technology, 1999, 35(4): 336-361.
[9]Mawhinney J. R. Design of water mist fire suppression systems for shipboard enclosures[A]. International Conference on water mist fire suppression systems[C]. Sweden: National Research Council, 1993: 16-44.
[10]Peizhong Yang, Tao Liu, Xian Qin. Experimental and numerical study on water mist suppression system on room fire [J]. Building and Environment, 2010 (45): 2309-2316.
[11]A. Jenft, A. Collin, P. Boulet, et al. Experimental and numerical study of pool fire suppression using water mist [J]. Fire Safety Journal, 2014, 67: 1-12.
[12]房玉东. 细水雾与火灾烟气相互作用的模拟研究[D]. 合肥:中国科学技术大学, 2006.
[13]房玉东.细水雾作用下烟气组分浓度变化规律的模拟研究[J].中国安全生产科学技术, 2012, 8(S1): 201-207. FANG Yu-dong. Study on variational principles of smoke component concentration with water mist applying[J]. Journal of Safety Science and Technology, 2012, 8(S1): 201-207.
[14]陆强,廖光煊,秦俊,等.细水雾灭油池火时各种影响因素的相对重要度分析[J].火灾科学, 2002, 11(3): 164-169. LU Qiang, LIAO Guangxuan, QIN Jun, et al. Analysis of relative significance of several influential factor for fire suppression by water mist[J]. Fire Safety Science, 2002, 11(3): 164-169.
[15]黄鑫,刘江虹,廖光煊,等.细水雾扑灭油池火的临界条件[J].燃烧科学与技术,2006, 12(4): 323-328. HUANG Xin, LIU Jianghong, LIAO Guangxuan, et al. Critical condition of pool fire suppression by water mist[J]. Journal of Combustion Science and Technology, 2006, 12(4): 323-328.
[16]李晓康,徐志胜. 受限空间脉冲细水雾系统关键参数试验与数值模拟研究[J].中国安全生产科学技术, 2017, 13(4): 46-52. LI Xiaokang, XU Zhisheng. Experimental and numerical simulation study on key parameter of pulse water mist system in confined space[J]. Journal of Safety Science and Technology, 2017, 13(4): 46-52.
[17]He Y. On experimental data reduction for zone model validation [J]. Fire Sciences, 1997(15): 144-161.

相似文献/References:

[1]杨陶.表面活性剂对细水雾雾流密度影响的实验研究[J].中国安全生产科学技术,2013,9(4):22.[doi:10.11731/j.issn.1673-193x.2013.04.004]
 YANG Tao.Experimental research on influences of surfactant on water mist flux density[J].JOURNAL OF SAFETY SCIENCE AND TECHNOLOGY,2013,9(11):22.[doi:10.11731/j.issn.1673-193x.2013.04.004]
[2]张培红,占 欢,张芸栗,等.地铁车厢机械排烟和细水雾耦合灭火效果研究*[J].中国安全生产科学技术,2009,5(4):10.
 ZHAN Pei hong,ZHAN Huan,ZHANG Yun li,et al.Study on the effect of fire suppression by coupling mechanical exhaust and water mist in subway carriage[J].JOURNAL OF SAFETY SCIENCE AND TECHNOLOGY,2009,5(11):10.
[3]李晓康,徐志胜.受限空间脉冲细水雾系统关键参数试验与数值模拟研究[J].中国安全生产科学技术,2017,13(4):46.[doi:10.11731/j.issn.1673-193x.2017.04.008]
 LI Xiaokang,XU Zhisheng.Experimental and numerical simulation study on key parameter of pulse water mist system in confined space[J].JOURNAL OF SAFETY SCIENCE AND TECHNOLOGY,2017,13(11):46.[doi:10.11731/j.issn.1673-193x.2017.04.008]
[4]张青松,程相静,白伟.细水雾添加剂抑制锂电池火灾最佳浓度研究[J].中国安全生产科学技术,2018,14(5):43.[doi:10.11731/j.issn.1673-193x.2018.05.007]
 ZHANG Qingsong,CHENG Xiangjing,BAI Wei.Study on optimum concentration of additives in water mist for suppression of lithium battery fire[J].JOURNAL OF SAFETY SCIENCE AND TECHNOLOGY,2018,14(11):43.[doi:10.11731/j.issn.1673-193x.2018.05.007]
[5]张杰,吴尚红,杨猛,等.喷头间距对城市隧道细水雾灭火的影响研究[J].中国安全生产科学技术,2018,14(12):119.[doi:10.11731/j.issn.1673-193x.2018.12.019]
 ZHANG Jie,WU Shanghong,YANG Meng,et al.Research on influence of sprinkler spacing on water mist fire extinguishing in urban tunnel[J].JOURNAL OF SAFETY SCIENCE AND TECHNOLOGY,2018,14(11):119.[doi:10.11731/j.issn.1673-193x.2018.12.019]
[6]罗振敏,等.含钾盐添加剂细水雾-惰性气体协同灭火实验研究*[J].中国安全生产科学技术,2023,19(5):164.[doi:10.11731/j.issn.1673-193x.2023.05.023]
 LUO Zhenmin,MENG Ziqi,et al.Experimental study on of synergistic fire extinguishing of fine water mist containing potassium salt additive and inert gas[J].JOURNAL OF SAFETY SCIENCE AND TECHNOLOGY,2023,19(11):164.[doi:10.11731/j.issn.1673-193x.2023.05.023]
[7]闫帅,王刚,洪林,等.细水雾与纵向通风对倾斜巷道火灾烟气运动规律影响研究*[J].中国安全生产科学技术,2024,20(2):188.[doi:10.11731/j.issn.1673-193x.2024.02.026]
 YAN Shuai,WANG Gang,HONG Lin,et al.Research on influence of water mist and longitudinal ventilation on smoke movement in inclined roadway fire[J].JOURNAL OF SAFETY SCIENCE AND TECHNOLOGY,2024,20(11):188.[doi:10.11731/j.issn.1673-193x.2024.02.026]
[8]赵道亮,方廷勇,廉锋.含F-500的低压细水雾抑制B类火灾的实验研究[J].中国安全生产科学技术,2010,6(4):9.
 ZHAO Dao-liang,FANG Ting-yong,LIAN Feng.Experimental research on low pressure water mist system in extinguishing oil fires with F-500[J].JOURNAL OF SAFETY SCIENCE AND TECHNOLOGY,2010,6(11):9.
[9]赵道亮,廉锋,刘英学.含微胶囊添加剂的低压细水雾厨房灭火实验研究*[J].中国安全生产科学技术,2009,5(6):62.
 ZHAO Dao liang,LIAN Feng,LIU Ying xue.Experimental research on low pressure water mist extinguishing system in cookroom with micelle encapsulator additive[J].JOURNAL OF SAFETY SCIENCE AND TECHNOLOGY,2009,5(11):62.

备注/Memo

备注/Memo:
湖南省自然科学基金青年基金项目(2017JJ3392);中国博士后科学基金面上项目(2016 M602430);中国科学技术大学火灾科学国家重点实验室开放课题(HZ2016-KF04)