|本期目录/Table of Contents|

[1]赵道亮,方廷勇,廉锋.含F-500的低压细水雾抑制B类火灾的实验研究[J].中国安全生产科学技术,2010,6(4):9-14.
 ZHAO Dao-liang,FANG Ting-yong,LIAN Feng.Experimental research on low pressure water mist system in extinguishing oil fires with F-500[J].JOURNAL OF SAFETY SCIENCE AND TECHNOLOGY,2010,6(4):9-14.
点击复制

含F-500的低压细水雾抑制B类火灾的实验研究()
分享到:

《中国安全生产科学技术》[ISSN:1673-193X/CN:11-5335/TB]

卷:
6
期数:
2010年4
页码:
9-14
栏目:
学术论著
出版日期:
2010-08-31

文章信息/Info

Title:
Experimental research on low pressure water mist system in extinguishing oil fires with F-500
文章编号:
1673-193X(2010)-04-0009-06
作者:
赵道亮1方廷勇2廉锋3
1.上海应用技术学院城市建设与安全工程学院,上海? 200235
2.安徽建筑工业学院土木工程学院,合肥? 230022
3.上海消防技术工程有限公司,上海? 200042
Author(s):
ZHAO Dao-liang1 FANG Ting-yong2 LIAN Feng3
1. School of City Construction and Safety Engineering, Shanghai Institute of Techology, Shanghai? 200235, China
2. School of Civil Engineering, Anhui University of Architecture, Hefei? 230022, China
3. Shanghai Fire Technology Engineering CO., LTD, Shanghai? 200042, China
关键词:
细水雾B类火灾微胶囊添加剂灭火有效性
Keywords:
-
分类号:
X928.7
DOI:
-
文献标志码:
A
摘要:
通过全尺寸实验研究低压细水雾对抑制和熄灭B类火灾的有效性。分别使用圆形和方形油盘,以汽油和柴油为燃料进行低压细水雾灭火实验,并进一步研究含微胶囊F-500添加剂的细水雾灭火效果。结果表明,低压细水雾对抑制和熄灭B类火具有一定的有效性,但容易出现灭大火容易灭小火难的现象,并且对于"角落火"难以扑灭。而添加了微胶囊F-500的低压细水雾,灭火效率较纯水细水雾提高约3~5倍,能有效扑灭死角火,同时提高火场能见度。分别用1%、3%、6%的F-500溶液作为灭火介质,实验表明,不同浓度的F-500溶液具有不同的灭火效果。综合考虑经济性和有效性因素:对于大多数B类火灾场合,F-500溶液的最佳配比为1%;对于危险性大或火灾荷载大的场合,微胶囊F-500水溶液的最佳配比为3%。
Abstract:
-

参考文献/References:

-

相似文献/References:

[1]杨陶.表面活性剂对细水雾雾流密度影响的实验研究[J].中国安全生产科学技术,2013,9(4):22.[doi:10.11731/j.issn.1673-193x.2013.04.004]
 YANG Tao.Experimental research on influences of surfactant on water mist flux density[J].JOURNAL OF SAFETY SCIENCE AND TECHNOLOGY,2013,9(4):22.[doi:10.11731/j.issn.1673-193x.2013.04.004]
[2]张培红,占 欢,张芸栗,等.地铁车厢机械排烟和细水雾耦合灭火效果研究*[J].中国安全生产科学技术,2009,5(4):10.
 ZHAN Pei hong,ZHAN Huan,ZHANG Yun li,et al.Study on the effect of fire suppression by coupling mechanical exhaust and water mist in subway carriage[J].JOURNAL OF SAFETY SCIENCE AND TECHNOLOGY,2009,5(4):10.
[3]赵道亮,廉锋,刘英学.含微胶囊添加剂的低压细水雾厨房灭火实验研究*[J].中国安全生产科学技术,2009,5(6):62.
 ZHAO Dao liang,LIAN Feng,LIU Ying xue.Experimental research on low pressure water mist extinguishing system in cookroom with micelle encapsulator additive[J].JOURNAL OF SAFETY SCIENCE AND TECHNOLOGY,2009,5(4):62.
[4]李晓康,徐志胜.受限空间脉冲细水雾系统关键参数试验与数值模拟研究[J].中国安全生产科学技术,2017,13(4):46.[doi:10.11731/j.issn.1673-193x.2017.04.008]
 LI Xiaokang,XU Zhisheng.Experimental and numerical simulation study on key parameter of pulse water mist system in confined space[J].JOURNAL OF SAFETY SCIENCE AND TECHNOLOGY,2017,13(4):46.[doi:10.11731/j.issn.1673-193x.2017.04.008]
[5]周洋,卜蓉伟,陈波,等.受限空间开口对细水雾灭火有效性影响实验研究[J].中国安全生产科学技术,2017,13(11):135.[doi:10.11731/j.issn.1673-193x.2017.11.022]
 ZHOU Yang,BU Rongwei,CHEN Bo,et al.Experimental study on influence of opening in confined space on suppression effectiveness of water mist[J].JOURNAL OF SAFETY SCIENCE AND TECHNOLOGY,2017,13(4):135.[doi:10.11731/j.issn.1673-193x.2017.11.022]
[6]张青松,程相静,白伟.细水雾添加剂抑制锂电池火灾最佳浓度研究[J].中国安全生产科学技术,2018,14(5):43.[doi:10.11731/j.issn.1673-193x.2018.05.007]
 ZHANG Qingsong,CHENG Xiangjing,BAI Wei.Study on optimum concentration of additives in water mist for suppression of lithium battery fire[J].JOURNAL OF SAFETY SCIENCE AND TECHNOLOGY,2018,14(4):43.[doi:10.11731/j.issn.1673-193x.2018.05.007]
[7]张杰,吴尚红,杨猛,等.喷头间距对城市隧道细水雾灭火的影响研究[J].中国安全生产科学技术,2018,14(12):119.[doi:10.11731/j.issn.1673-193x.2018.12.019]
 ZHANG Jie,WU Shanghong,YANG Meng,et al.Research on influence of sprinkler spacing on water mist fire extinguishing in urban tunnel[J].JOURNAL OF SAFETY SCIENCE AND TECHNOLOGY,2018,14(4):119.[doi:10.11731/j.issn.1673-193x.2018.12.019]
[8]罗振敏,等.含钾盐添加剂细水雾-惰性气体协同灭火实验研究*[J].中国安全生产科学技术,2023,19(5):164.[doi:10.11731/j.issn.1673-193x.2023.05.023]
 LUO Zhenmin,MENG Ziqi,et al.Experimental study on of synergistic fire extinguishing of fine water mist containing potassium salt additive and inert gas[J].JOURNAL OF SAFETY SCIENCE AND TECHNOLOGY,2023,19(4):164.[doi:10.11731/j.issn.1673-193x.2023.05.023]
[9]闫帅,王刚,洪林,等.细水雾与纵向通风对倾斜巷道火灾烟气运动规律影响研究*[J].中国安全生产科学技术,2024,20(2):188.[doi:10.11731/j.issn.1673-193x.2024.02.026]
 YAN Shuai,WANG Gang,HONG Lin,et al.Research on influence of water mist and longitudinal ventilation on smoke movement in inclined roadway fire[J].JOURNAL OF SAFETY SCIENCE AND TECHNOLOGY,2024,20(4):188.[doi:10.11731/j.issn.1673-193x.2024.02.026]

备注/Memo

备注/Memo:
收稿日期:2010-05-25
作者简介:赵道亮,副教授,博士。
基金项目:上海高校选拔培养优秀青年教师科研专项基金(编号:YYY-07010);上海应用技术学院引进人才科研启动项目(编号:YJ2007-29);国家自然科学基金(编号:50976001)资助
更新日期/Last Update: