[1]Dyer J. H. Water mist fire suppression systems: application assessment test on full-scale enclosure [J]. Fire Engineers Journal, 1997,11:27-32.
[2]Ural E. A., Bill R. G. Fire Suppression Performance Testing of Water Mist Systems for Combustion Turbine Enclosures[A]. Proceedings of Halon Alternatives Technical Working Conference[C]. Albuquerque: New Mexico Engineering Research Institute, 1995: 449-456.
[3]Zhigang Liu, Andrew K. Kim, Joseph Z. Su. Examination of the extinguishment performance of a water mist system using continuous and cycling discharges[J]. Fire Technology, 1999, 35(4):336-360.
[4]J.C.Kapoor, Meenakshi Gupta, A.K.Kapoor. Comparative study on fire suppression performance of 25μm water mist in continuous and pulsed discharge mode[A]. 10th International Conference on Liquid Atomization and Spray Systems[C]. Kyoto: Institute for Liquid Atomization and Spray Systems-Japan, 2006: 77-83.
[5]McGrattan K., McDermott R., Hostikka S., et al. Fire dynamics simulator (Version5) user’s guide[M]. Maryland: NIST Special Publication 1019-5, 2014:86-91.
[6]林霖,房玉东,翁韬,等. 细水雾与火灾烟气相互作用的实验和数值模拟研究[J]. 中国工程科学,2007,10(10):72-77.
LIN Lin, FANG Yudong, WENG Tao, et el. An experimental and numerical study on the interaction between water mist and smoke[J]. Engineering Sciences, 2007, 10(10): 72-77.
[7]Zhang W., Ryder N., Roby R.J., et al. Modeling of the combustion in compartment fires using large eddy simulation approach [A]. Proceedings of the 2001 Fall Technical Meeting[C]. Pittsburgh: Combustion Institute, 2001: 223-230.
[8]McGrattan K., Hostikka S., Floyd J., et al. Fire dynamics simulator (Version5) technical reference guide[M]. Maryland: NIST special publication 1018-5, 2014:139-142.
[9]Hamins A., McGrattan K. Reduced-scale experiments on the water suppression of a rack-storage commodity fire for calibration of a CFD fire model[A]. Fire Safety Science: Proceedings of the Seventh International Symposium[C]. London: International Association for Fire Safety Science, 2002: 457-468.
[10]牛国庆. 细水雾抑制室内火灾的理论与试验研究[D]. 长沙:中南大学, 2007.
[11]陆强,李钙,廖光煊,等. 油池火中细水雾强化火焰现象研究[J]. 中国工程科学,2006,8(7):78-82.
LU Qiang, LI Gai, LIAO Guangxuan, et al. Investigation of fire enhancement in pool fire by water mist[J]. Engineering Science, 2006, 8(7):78-82.
[1]赵道亮,方廷勇,廉锋.含F-500的低压细水雾抑制B类火灾的实验研究[J].中国安全生产科学技术,2010,6(4):9.
ZHAO Dao-liang,FANG Ting-yong,LIAN Feng.Experimental research on low pressure water mist system in extinguishing oil fires with F-500[J].JOURNAL OF SAFETY SCIENCE AND TECHNOLOGY,2010,6(4):9.
[2]杨陶.表面活性剂对细水雾雾流密度影响的实验研究[J].中国安全生产科学技术,2013,9(4):22.[doi:10.11731/j.issn.1673-193x.2013.04.004]
YANG Tao.Experimental research on influences of surfactant on water mist flux density[J].JOURNAL OF SAFETY SCIENCE AND TECHNOLOGY,2013,9(4):22.[doi:10.11731/j.issn.1673-193x.2013.04.004]
[3]张培红,占 欢,张芸栗,等.地铁车厢机械排烟和细水雾耦合灭火效果研究*[J].中国安全生产科学技术,2009,5(4):10.
ZHAN Pei hong,ZHAN Huan,ZHANG Yun li,et al.Study on the effect of fire suppression by coupling mechanical exhaust and water mist in subway carriage[J].JOURNAL OF SAFETY SCIENCE AND TECHNOLOGY,2009,5(4):10.
[4]赵道亮,廉锋,刘英学.含微胶囊添加剂的低压细水雾厨房灭火实验研究*[J].中国安全生产科学技术,2009,5(6):62.
ZHAO Dao liang,LIAN Feng,LIU Ying xue.Experimental research on low pressure water mist extinguishing system in cookroom with micelle encapsulator additive[J].JOURNAL OF SAFETY SCIENCE AND TECHNOLOGY,2009,5(4):62.
[5]周洋,卜蓉伟,陈波,等.受限空间开口对细水雾灭火有效性影响实验研究[J].中国安全生产科学技术,2017,13(11):135.[doi:10.11731/j.issn.1673-193x.2017.11.022]
ZHOU Yang,BU Rongwei,CHEN Bo,et al.Experimental study on influence of opening in confined space on suppression effectiveness of water mist[J].JOURNAL OF SAFETY SCIENCE AND TECHNOLOGY,2017,13(4):135.[doi:10.11731/j.issn.1673-193x.2017.11.022]
[6]张青松,程相静,白伟.细水雾添加剂抑制锂电池火灾最佳浓度研究[J].中国安全生产科学技术,2018,14(5):43.[doi:10.11731/j.issn.1673-193x.2018.05.007]
ZHANG Qingsong,CHENG Xiangjing,BAI Wei.Study on optimum concentration of additives in water mist for suppression of lithium battery fire[J].JOURNAL OF SAFETY SCIENCE AND TECHNOLOGY,2018,14(4):43.[doi:10.11731/j.issn.1673-193x.2018.05.007]
[7]张杰,吴尚红,杨猛,等.喷头间距对城市隧道细水雾灭火的影响研究[J].中国安全生产科学技术,2018,14(12):119.[doi:10.11731/j.issn.1673-193x.2018.12.019]
ZHANG Jie,WU Shanghong,YANG Meng,et al.Research on influence of sprinkler spacing on water mist fire extinguishing in urban tunnel[J].JOURNAL OF SAFETY SCIENCE AND TECHNOLOGY,2018,14(4):119.[doi:10.11731/j.issn.1673-193x.2018.12.019]
[8]罗振敏,等.含钾盐添加剂细水雾-惰性气体协同灭火实验研究*[J].中国安全生产科学技术,2023,19(5):164.[doi:10.11731/j.issn.1673-193x.2023.05.023]
LUO Zhenmin,MENG Ziqi,et al.Experimental study on of synergistic fire extinguishing of fine water mist containing potassium salt additive and inert gas[J].JOURNAL OF SAFETY SCIENCE AND TECHNOLOGY,2023,19(4):164.[doi:10.11731/j.issn.1673-193x.2023.05.023]
[9]闫帅,王刚,洪林,等.细水雾与纵向通风对倾斜巷道火灾烟气运动规律影响研究*[J].中国安全生产科学技术,2024,20(2):188.[doi:10.11731/j.issn.1673-193x.2024.02.026]
YAN Shuai,WANG Gang,HONG Lin,et al.Research on influence of water mist and longitudinal ventilation on smoke movement in inclined roadway fire[J].JOURNAL OF SAFETY SCIENCE AND TECHNOLOGY,2024,20(4):188.[doi:10.11731/j.issn.1673-193x.2024.02.026]
[10]王帅,蔡睿,吴彬,等.细水雾抑制熄灭受限空间变压器火灾实验研究[J].中国安全生产科学技术,2025,21(1):169.[doi:10.11731/j.issn.1673-193x.2025.01.022]
WANG Shuai,CAI Rui,WU Bin,et al.Experimental study on suppressing and extinguishing of transformer fire in confined space with fine water mist[J].JOURNAL OF SAFETY SCIENCE AND TECHNOLOGY,2025,21(4):169.[doi:10.11731/j.issn.1673-193x.2025.01.022]