|本期目录/Table of Contents|

[1]周杰,陈皓粤,汪益敏,等.下沉式地铁车辆段环境噪声特性试验研究*[J].中国安全生产科学技术,2021,17(7):178-184.[doi:10.11731/j.issn.1673-193x.2021.07.029]
 ZHOU Jie,CHEN Haoyue,WANG Yimin,et al.Experimental study on ambient noise characteristics of sinking metro depot[J].JOURNAL OF SAFETY SCIENCE AND TECHNOLOGY,2021,17(7):178-184.[doi:10.11731/j.issn.1673-193x.2021.07.029]
点击复制

下沉式地铁车辆段环境噪声特性试验研究*
分享到:

《中国安全生产科学技术》[ISSN:1673-193X/CN:11-5335/TB]

卷:
17
期数:
2021年7期
页码:
178-184
栏目:
职业安全卫生管理与技术
出版日期:
2021-07-31

文章信息/Info

Title:
Experimental study on ambient noise characteristics of sinking metro depot
文章编号:
1673-193X(2021)-07-0178-07
作者:
周杰陈皓粤汪益敏卢鸿钧刘品言
(1.华南理工大学 土木与交通学院,广东 广州 510640;
2.广州地铁设计研究院股份有限公司,广东 广州 510010)
Author(s):
ZHOU Jie CHEN Haoyue WANG Yimin LU Hongjun LIU Pinyan
(1.School of Civil Engineering and Transportation,South China University of Technology,Guangzhou Guangdong 510640,China;
2.Guangzhou Metro Design and Research Institute Co.,Ltd.,Guangzhou Guangdong 510010,China)
关键词:
下沉式地铁车辆段环境噪声现场测试声场特性
Keywords:
sinking metro depot ambient noise field measurement sound field characteristic
分类号:
X951
DOI:
10.11731/j.issn.1673-193x.2021.07.029
文献标志码:
A
摘要:
针对下沉式地铁车辆段环境噪声问题,采用问卷调查与现场实测相结合的方法,对下沉式地铁车辆段环境噪声特性开展研究。结果表明:通风噪声是下沉式地铁车辆段主要噪声源,其次为列车噪声;办公区域噪声强度超出标准限值3~5 dB(A),其中1 000 Hz左右中频段噪声带给人的烦恼度最高;检修库内存在严重低频噪声,尽管各测点均未超过标准限值,但由于风机长期24 h运行,仍会引起员工不舒适感;上盖司机公寓内二次结构噪声强度不满足环境标准限值要求,对公寓居民睡眠产生不良影响;结构振动噪声具有明显的低频特征,主要对16~250 Hz起作用,其中250 Hz频段超标最严重。
Abstract:
Aiming at the problem of environmental noise generated in the sinking metro depot,a combination method of questionnaire survey and field measurement was used to study the environmental noise characteristics of the sinking metro depot.The results showed that the ventilation noise was the main noise source of sinking metro depot,followed by the train noise.The noise intensity in the office area exceeded the standard limits by 3~5 dB,and among which,the mid-frequency noise around 1000 Hz brought the highest annoying degree to people.There was a serious low-frequency noise influence in the maintenance garage,and although all the measurement points did not exceed the standard limit,the long-term 24-hour operation of the ventilator would still cause discomfort to the employees.The noise intensity of the secondary structure in the upper driver’s apartment exceeded the environmental standard limit,which would affect the sleep of the residents in the apartment.The noise caused by the structural vibration mainly affected 16~250 Hz,with obvious low-frequency characteristics,and among them,250 Hz was the frequency band with the most serious violation,which should be paid more attention in the subsequent noise control.

参考文献/References:

[1]陈艳明,冯青松,刘庆杰,等.下沉式地铁车辆段咽喉区车致振动特性[J].交通运输工程学报,2020,20(3):51-60. CHEN Yanming,FENG Qingsong,LIU Qingjie,et al.Train-induced vibration characteristics in throat area of sinking metro depot [J].Journal of Traffic and Transportation Engineering,2020,20(3):51-60.
[2]TAO Z,WANG Y,ZOU C,et al.Assessment of ventilation noise impact from metro depot with over-track platform structure on workers and nearby inhabitants[J].Environment Science Pollution Research,2019(26):9203-9218.
[3]European Environment Agency.Noise in Europe 2014 [R].Publications Office of the European Union:Luxembourg,2014.
[4]中华人民共和国生态环境部.中国环境噪声污染防治报告[R/OL].(2020-06-22)[2020-06-22].http://www.doc88.com/p-20099048893865.htm.
[5]陈曦.地下餐饮空间声环境研究[D].哈尔滨:哈尔滨工业大学,2013.
[6]曹枚根,莫娟,莫海枢,等.地下变电站结构振动与噪声相关性及预估方法[J].中国电机工程学报,2014,34(33):5998-6005. CAO Meigen,MO Juan,MO Haishu,et al.Correlation analysis and prediction method on structure vibration and noise caused by transformer in underground substation[J].Proceedings of the CSEE,2014,34(33):5998-6005.
[7]刘茜,史聪灵,伍彬彬,等,城市轨道交通站台噪声测量研究[J].中国安全生产科学技术,2017,13(11):143-148. LIU Qian,SHI Congling,WU Binbin et al.Analysis on noise status of urban railway platform[J].Journal of Safety Science and Technology,2017,13(11):143-148.
[8]中华人民共和国国家质量监督检验检疫总局 中国国家标准化管理委员会.声学 应用社会调查和社会声学调查评价噪声烦恼度:GB/Z 21233—2007[S].北京:中国标准出版社,2007.
[9]国家质检总局.声环境质量标准:GB 3096—2008[S].北京:中国环境科学出版社,2008.
[10]国家质量监督检验检疫总局 环境保护部.城市轨道交通引起建筑物振动与二次辐射噪声限值及其测量方法标准:JGJ/T 170—2009[S].北京:中国建筑工业出版社,2009.
[11]中华人民共和国国家计划委员会.工业企业噪声控制设计规范:GB/T 50087—2013[S].北京:中国建筑工业出版社,2013.
[12]陈思宇,章斯宇.中国传媒大学校园环境噪声调查与评价[J].中国传媒大学学报(自然科学版),2019,26(6):60-66. CHEN Siyu,ZHANG Siyu.Investigation and evaluation of campus environmental noise in communication university of China[J].Journal of Communication University of China,2019,26(6):60-66.

相似文献/References:

备注/Memo

备注/Memo:
收稿日期: 2021-01-04
* 基金项目: 广东省科技计划项目(2017A050501005)
作者简介: 周杰,硕士研究生,主要研究方向为城市轨道交通噪声。
通信作者: 汪益敏,博士,教授,主要研究方向为地铁环境振动与噪声。
更新日期/Last Update: 2021-08-05