|本期目录/Table of Contents|

[1]张守鑫,杨博,周川,等.滤毒罐寿命失效指示器的研究进展[J].中国安全生产科学技术,2019,15(8):51-57.[doi:10.11731/j.issn.1673-193x.2019.08.008]
 ZHANG Shouxin,YANG Bo,ZHOU Chuan,et al.Research progress on endofservicelife indicator for canisters[J].JOURNAL OF SAFETY SCIENCE AND TECHNOLOGY,2019,15(8):51-57.[doi:10.11731/j.issn.1673-193x.2019.08.008]
点击复制

滤毒罐寿命失效指示器的研究进展
分享到:

《中国安全生产科学技术》[ISSN:1673-193X/CN:11-5335/TB]

卷:
15
期数:
2019年8期
页码:
51-57
栏目:
职业安全卫生管理与技术
出版日期:
2019-08-31

文章信息/Info

Title:
Research progress on endofservicelife indicator for canisters
文章编号:
1673-193X(2019)-08-0051-07
作者:
张守鑫12杨博12周川2原博2司芳芳2杨小兵12
(1.国民核生化灾害防护国家重点实验室,北京 100191;
2.防化研究院,北京 100191)
Author(s):
ZHANG Shouxin12YANG Bo12ZHOU Chuan2YUAN Bo2SI Fangfang2YANG Xiaobing12
(1.State Key Laboratory of NBC Protection for Civilian,Beijing 100191,China;
2.Research Institute of Chemical Defense,Beijing 100191,China)
关键词:
滤毒罐寿命失效指示器传感器比色有机蒸气
Keywords:
canister endofservicelife indicator (ESLI) sensor colorimetry organic vapor
分类号:
X965;TJ92
DOI:
10.11731/j.issn.1673-193x.2019.08.008
文献标志码:
A
摘要:
滤毒罐寿命失效指示器能保障有毒有害环境下作业人员的生命安全。为了全面了解滤毒罐寿命失效指示器的研究进展,基于滤毒罐失效指示器的概念、原理和政策,介绍滤毒罐对有机蒸气有效防护时间的评估模型及其应用;通过介绍近年来主动式和被动式2类滤毒罐寿命失效指示器的研究进展,指出被动式比色型寿命失效指示器由于成本低廉是目前研究较为广泛、成熟的技术,而成本仍然是制约主动式寿命失效指示器的主要因素;最后,提出滤毒罐寿命失效指示器在职业防护领域和军事领域的发展趋势和应用前景。
Abstract:
The endofservicelife indicator (ESLI) of canisters can protect the life safety of workers under the poisonous and harmful environment.In order to fully understand the research progress on the ESLI of canisters,based on the concept,principle and policy of ESLI,the evaluation models for the effective protection time of canisters for the organic vapors and their application were introduced.Through introducing the research progress on the active and passive ESLI for canisters in recent years,it was pointed out that the passive colorimetric type ESLI was the relatively extensive and mature technology because of its low cost at present,while the cost was still the main restrictive factor for the active ESLI.Finally,the development trend and application prospect of ESLI in the fields of occupational protection and military were put forward.

参考文献/References:

[1]李小银.过滤式防毒面具的防护原理[J].中国个体防护装备,2002(3):38-40.LI Xiaoyin.Protective principles of air-purifying respirators[J].China Personal Protective Equipment,2002(3):38-40.
[2]REIST P,REX F.Odor detection and respirator cartridge replacement[J].American Industrial Hygiene Association Journal,1977,38:563-566.
[3]YABHCK M.Indicating gas-mask canister:US,1537519[P].1925-05-12.
[4]GARDNER,P D.Multi-agent end-of-service-life indicator for resprator filters:US,7442237B1[P].2008-10-28.
[5]FAVAS G.End of service life indicator (ESLI) for respirator cartridges part I: Literature review.DSTO-TN-0657[R].Defence Science and Technology Organisation,Australia Government Department of Defense,2005.
[6]KING B H,RUMINSKI A M,SNYDER J L,et al.Optical-fiber mounted porous silicon photonic crystals for sensing organic vapor breakthrough in activated carbon[J].Adv.Mater.,2007,19(45):30-44.
[7]SNYDER J L.End-of-service life sensors and models[C]//Technical Support Working Group,Personal Protective Equipment Conference,Fort Lauderdale,FL,2007.
[8]SNYDERJ L.End-of-service-life sensor systems for personal protective equipment[C]//Scientific Conference on Chembio Defense Research,Timonium,MD,2007.
[9]BEDAIR SS,FEDDER G K.CMOS MEMS oscillator for gas chemical detection[C]//Proceedings of the IEEE Sensors,2004,955-958.
[10]JONES J A.Respirator cartridge end-of-service life indicator:US,4530706[P].1985-06-23.
[11]CURADOL.Service life indicator for respirator cartridge:US,6497756[P].2002-12-24.
[12]JAGERH.Device for removing one or more undesirable or dangerous substances from a gas vapor mixture and a gas mask comprising such a device:US,5944873[P].1999-08-31.
[13]ROSE-PHERSSON S,WILLIAMS M L.Integration of sensor technologies in respirator vapor cartridges as end-of-service life indicators:literature and manufacturer’s review and research roadmap.NRL/MR/6112-05-8875[R].Naval Research Laboratory,2005.
[14]陈友生,袁晓华,周朝华,等.滤毒罐失效指示器的研究概况[J].中国个体防护装备,2009(1):12-13.CHEN Yousheng,YUAN Xiaohua,ZHOU Chaohua,et al.A review of the development of end-of-service-life indicator for respirator cartridges [J].China Personal Protective Equipment,2009(1):12-13.
[15]NIOSH.“Determination of End-of-Service-Life Indicator (ESLI) Drop test”,Air-Purifying Respirators Standard Testing Procedure (STP) RCT-APR-STP-0060.Revision 1.1[R].Pittsburgh,PA,2005.
[16]NIOSH.“Determination of End-of-Service-Life Indicator (ESLI) test”,Air-Purifying Respirators Standard Testing Procedure (STP) RCT-APR-STP-0066.Revision 1.1[R].Pittsburgh,PA,2005.
[17]International Society for Respiratory Protection Conference[C]//Boston,MA,September 23-27,2012.JISRP,2012,29(2):108.
[18]COHEN H J,GARRISON R P.Development of a field method for evaluating the service life of organic vapor cartridges:results of laboratory testing using carbon tetrachloride [J].American Industrial Hygiene Association Journal,1989,50(9):486-495.
[19]WOOD G O,MOYER E M.A review of the wheeler equation and comparison of its applications to organic vapor respirator cartridge breakthrough data[J].American Industrial Hygiene Association Journal,1989,50 (9):400-407.
[20]COHEN H J,GARRISON R P.Development of a field method for evaluating the service lives of organic vapor cartridges:results of laboratory testing using carbon tetrachloride part II:humidity effects[J].American Industrial Hygiene Association Journal,1990,51(11):575-580.
[21]COHEN H J,GARRISON R P.Development of a field method for evaluating the service lives of organic vapor cartridges part III:results of laboratory testing using binary organic vapor mixtures[J].American Industrial Hygiene Association Journal,1991,52(1):34-43.
[22]WOOD G O.Estimating service lives of organic vapor cartridges[J].American Industrial Hygiene Association Journal,1994,55(1):11-15.
[23]WOOD G O,LODEWYCKX P.An extended equation for rate coefficients for adsorption of organic vapors and gases on activated carbons in air-purifying respirator cartridges[J].American Industrial Hygiene Association Journal,2003,64(5):646-650.
[24]WOOD G O.Estimating service lives of organic vapor cartridges II:A single vapor at all humidities[J].Journal of Occupational and Environmental Hygiene,2004(1):472-492.
[25]WOOD G O,SNYDER J L.Estimating service lives of organic vapor cartridges iii:multiple vapors at all humidities [J].Journal of Occupational and Environmental hygiene,2007( 4):363-374.
[26]MCGILL R A,NGUYEN V K,CHUNG R,et al.The “NRL-SAWRHINO”:a nose for toxic gases[J].Sensors and Actuators B,2000(65):10-13.
[27]BERNARD P.End-of-service indicator including porous waveguide for Respirator cartridge:US,6375725B1[P].2002-04-23.
[28]CARON S,BERNARD P,VERNON M,et al.Porous glass optical fiber sensor as an end-of-service indicator for respiratory cartridges[J].Sensors and Actuators B,2004(102):198-206.
[29]SCOTT DUNCANE J.Respirator end-of-service life probe:US,7894069B2[P].2011-11-22.
[30]吴泰顺.有失效指示的过滤式防有机毒气呼吸面具:中国,1281738A[P].2001-01-31.
[31]ROEHL J E,CARAHER T W,KALMES K A,et al.Residual life indicators-point chemical detectors used to measure the capacity of activated carbon in protective garments,gas mask filters,and collective protection filters[C]//Proceedings of the First Joint Conference on Point Detection for Chemical and Biological Defense,Williamsburg,VA,2000.
[32]LIU H L.End of service life indicator for organic vapor respirator filter cartridge:US,8859995B2[P].2014-10-14.
[33]GREENAWALD L A,BOSS G R,REEDER A,et al.Development of a hydrogen sulfide end-of-service-life indicator for respirator cartridges using cobinamide[J].Sensors and Actuators B,2016(230):658-666.
[34]GREENAWALD L A,SNYDER J L,FRY NL.Development of a cobinamide-based end-of-service-life indicatorfor detection of hydrogen cyanide gas[J].Sensors and Actuators B,2015(221):379-385.
[35]DING F.Method and apparatus for integrating chemicaland environmental sensors into an air purification filter through a reusable sensor port:US,9504859B2[P].2016-11-29.
[36]SPITLERM T.Dye desorption molecular indicator:WO0003226[P].2000-01-20.
[37]WATSONE.Residual life indicator:US,6701864B2[P].2004-03-09.
[38]RAKOW N A,WENDLAND M S,TREND J E,et al.Visual Indicator for Trace Organic Volatiles[J].Langmuir,2010,26(6):3767-3770.
[39]BUDD P M,GHANEM B S,MAKHSEED S,et al.Polymers of intrinsic microporosity (PIMs):robust,solution-processale,organic nanoporous materials[J].Chemical Communications,2004(2):230-231.
[40]BUDD P M,MCKEOWN N B,FRITSCH D.Free volume and intrinsic microporosity in polymers[J].Journal of Materials Chemistry,2005(15):1977-1986.
[41]THOMAS J CH,TREND J E,RAKOW N A.Optical sensor for diverse organic vapors at ppm concentration ranges[J].Sensors,2011(11):3267-3280.
[42]THOMAS W.HOLMQUIST-BROWN.Filter cartridge having cover for masking service life indicator:US,8336543B2[P].2012-12-25.
[43]CHECKY M,FRANKEL K,GODDARD D,et al.Evaluation of a passive optical based end of service life indicator (ESLI) for organic vapor respirator cartridges[J].Journal of Occupational and Environmental Hygiene,2016,13(2):112-120.

相似文献/References:

[1]谭雯莉,杨博,杨小兵,等.仪器法与化学法测定防毒面具滤毒罐苯蒸气防护时间研究*[J].中国安全生产科学技术,2021,17(2):183.[doi:10.11731/j.issn.1673-193x.2021.02.029]
 TAN Wenli,YANG Bo,YANG Xiaobing,et al.Study on protection time of gas mask canister against benzene vapor measured by instrumental method and chemical method[J].JOURNAL OF SAFETY SCIENCE AND TECHNOLOGY,2021,17(8):183.[doi:10.11731/j.issn.1673-193x.2021.02.029]

备注/Memo

备注/Memo:
收稿日期: 2019-06-21
* 基金项目: 国民核生化灾害防护国家重点实验室基金项目(SKLNBC2018-07)
作者简介: 张守鑫,硕士,工程师,主要研究方向为防护技术与材料。
通信作者: 杨小兵,博士,副研究员,主要研究方向为防护技术与材料。
更新日期/Last Update: 2019-09-04