[1]姚小林.卡源故障下悬挂链式辐照室火灾危险性研究[J].中国安全生产科学技术,2017,13(4):148-152.[doi:10.11731/j.issn.1673-193x.2017.04.024]
 YAO Xiaolin.Study on fire risk of irradiation room with hanging chain conveyor under the fault of stuck radioactive sources[J].JOURNAL OF SAFETY SCIENCE AND TECHNOLOGY,2017,13(4):148-152.[doi:10.11731/j.issn.1673-193x.2017.04.024]
点击复制

卡源故障下悬挂链式辐照室火灾危险性研究
分享到:

《中国安全生产科学技术》[ISSN:1673-193X/CN:11-5335/TB]

卷:
13
期数:
2017年4期
页码:
148-152
栏目:
现代职业安全卫生管理与技术
出版日期:
2017-04-30

文章信息/Info

Title:
Study on fire risk of irradiation room with hanging chain conveyor under the fault of stuck radioactive sources
文章编号:
1673-193X(2017)-04-0148-05
作者:
姚小林12
1.西南交通大学 地球科学与环境工程学院,四川 成都 610031;2.泸州职业技术学院,四川 泸州 646000
Author(s):
YAO Xiaolin12
1.Faculty of Geosciences and Environmental Engineering, Southwest Jiaotong University, Chengdu Sichuan 610031, China;2.Luzhou Vacational and Technical College, Luzhou Sichuan 646000, China
关键词:
辐照室卡源火灾危险性FDS
Keywords:
irradiation room stuck radioactive sources fire risk FDS
分类号:
TU545;X946
DOI:
10.11731/j.issn.1673-193x.2017.04.024
文献标志码:
A
摘要:
为了分析悬挂链式辐照室的火灾危险性,采用实验测定得出室内典型辐照物品的点着温度,通过设置3组火灾场景模拟得到卡源故障下各火灾场景辐照室内温度变化曲线。结果表明:各火灾场景卡源初期1 h,温度上升速度较快。随着时间的增长,室内温度不断上升,但上升速率逐渐放缓。在火灾场景A,B,C等3组条件下卡源故障分别发生9,4,2.4 d后,室内局部温度能达到210℃,室内辐照物品有可能被引燃。
Abstract:
To analyze the fire risk of irradiation room with hanging chain conveyor, the ignition temperatures of typical radiation cargos in the irradiation room were measured through the experiment, and the variation curves of temperature in the irradiation room under the fault of stuck radioactive sources in each fire scenario were obtained through the simulation by setting three fire scenarios. The results showed that the temperature rises rapidly within 1 hour in the initial stage of stuck radioactive sources under each fire scenario. The temperature in the irradiation room rises continually with the growth of time, but the rising rate slows down gradually. The local temperature in the irradiation room can reach 210 ℃ when the fault of stuck radioactive sources occurs for 9 days, 4 days and 2.4 days respectively in three fire scenarios A, B and C, so the radiation cargos in the irradiation room may be ignited.

参考文献/References:

[1]李德平,陈明峻. 使用密封放射源的装置在设计与运行中应当注意的一些安全问题[J].辐射防护,1985,5(3):161-168. LI Deping, CHEN Mingjun.Safety considerations in design and operation of installations using sealed sources[J].Radiation Protection,1985,5(3):161-168.
[2]俞荣生. 13次倒装钴源的现场监督及受照剂量控制对策[J].中国辐射卫生,2001,10(3):133-134. YU Rongsheng.Monitor in situ and personnel dose control in Cobalt- 60 source replenishment[J].Chinese Journal of Radiological Health,2001,10(3):133-134.
[3]郑美扬,金国华,沈根芳.60Co辐照室环境放射防护评价[J].核电子学与探测技术,2010,30(9):1224-1225. ZHENG Meiyang,JIN Guohua,SHEN Genfang.The radiation protection environmental assesment for 60Co irradiation room[J].Nuclear Electronics & Detection Technology,2010,30(9):1224-1225.
[4]王传真.γ辐射装置经济有效运行若干问题[M].北京:北京原子能出版社,1997:2-5.
[5]刘海生,许献洪,顾国兴,等. 60Co辐照装置的辐射防护监测[J].同位素,2006,19(1):57-62. LIU Haisheng, XU Xianhong, GU Guoxing, et al.The radiation protection assesment for 60co irradiation equipment[J].Journal of Isotopes,2006,19(1):57-62.
[6]史建君,赵小俊,付俊杰. 60Co辐照室增源后剂量场的剂量测定[J].核农学报,1999,13(2):81-85. SHI Jianjun,ZHAO Xiaojun,FU Junjie.Measurement of dose field after supplement source in 60co irradiation chamber[J].Acta Agriculturae Nucleatae Sinica,1999,13(2):81-85.
[7]葛良全,周四春.核辐射测量方法[M].成都:成都理工大学核技术与自动化工程学院,2007:2-10.
[8]马崇智.放射性同位素手册[ M].北京:科学出版社,1979:394
[9]刘雄华,王正明.放射卫生防护基本知识[M].武汉:武汉测绘科技大学出版社,1991: 82.
[10]范深根,张永祥,许昌恒. 60Co源辐照装置安全技术措施和经验[J].原子能科学技术,1989,23(3):88-93. FAN Gensheng,ZHANG Yongxiang, XU Changheng.Safe technique and experience of 60Co irradiator[J].Atomic Energy Science and Technology,1989,23(3):88-93.
[11]李小华,唐朝.积分法评估60Co工业辐照装置卡源事故剂量[J].核电子学与探测技术,2016,36(1):30-33. LI Xiaohua,TANG Chao.Dose assessment of source locked accident in Cobalt-60 industry radiation facility based on integral method[J].Nuclear Electronics & Detection Technology,2016,36(1):30-33.
[12]张之华,米向秒,李润东.CITP-Ⅱ辐照装置的安全性及可行性研究[J].原子能科学技术,2014,48:410-414. ZHANG Zhihua,MI Xiangmiao,LI Rundong.Safety and feasibility research of CITP-Ⅱ irradiation device[J].Atomic Energy Science and Technology,2014,48:410-414.
[13]陈曦,童宁. 辐照室潜在事故可能性及对策建议[J].人类工效学,2000,6(2):56-57. CHEN Xi,TONG Ning.Research on problems and countermeasures of irradiation room[J].Chinese Journal of Ergonomics,2000,6(2):56-57.
[14]乔海涛, 李航, 涂兴明. 辐照装置火灾隐患分析及防治研究[J]中国辐射卫生,2015,24(5):522-524. QIAO Haitao,LI Hang,TU Xingming. Study on fire hidden trouble and countermeasures of Irradiation room[J].Chinese Journal of Radiological Health,2015,24(5):522-524.
[15]栗朝阳,孙绍玉,郭志新. 关于辐照企业辐射性火灾的几点思考[J].消防科学与技术,2009,28(11):870-872.
[16]Korhonen T,Hstikka S,Heliovaara S,et al. Evacuation Module for Fire Dynamics Simulator[A]. Proceedings of the 11th International Conference on Fire Science and Engineering[C]. London,UK:2007:1443-1448.
[17]Korhonen T,Hstikka S,Heliovaara S,et al. Modeling Social Interactions in Fire Evacuation[A].Proceedings of the 7th International Conference on Performance-Based Codes and Fire Safety Design Methods[C]. MD, USA:2008: 241-250.

相似文献/References:

备注/Memo

备注/Memo:
泸州职业技术学院基金项目
更新日期/Last Update: 2017-05-11