[1]高彦,宋立冬,杜一锋,等.基于PLM的矿用低压变频器漏电机理的研究[J].中国安全生产科学技术,2016,12(10):130-135.[doi:10.11731/j.issn.1673-193x.2016.10.022]
 GAO Yan,SONG Lidong,DU Yifeng,et al.Research on electric leakage mechanism of low voltagefrequency converter for mining based on PLM[J].JOURNAL OF SAFETY SCIENCE AND TECHNOLOGY,2016,12(10):130-135.[doi:10.11731/j.issn.1673-193x.2016.10.022]
点击复制

基于PLM的矿用低压变频器漏电机理的研究
分享到:

《中国安全生产科学技术》[ISSN:1673-193X/CN:11-5335/TB]

卷:
12
期数:
2016年10期
页码:
130-135
栏目:
现代职业安全卫生管理与技术
出版日期:
2016-10-30

文章信息/Info

Title:
Research on electric leakage mechanism of low voltagefrequency converter for mining based on PLM
作者:
高彦宋立冬杜一锋黄丽平童灵犀秦泽希
中国矿业大学(北京)机电与信息工程学院,北京 100083)
Author(s):
GAO Yan SONG Lidong DU Yifeng HUANG Liping TONG Lingxi QIN Zexi
School of Mechanical Electronic & Information Engineering, China University of Mining & Technology, Beijing, Beijing 100083, China
关键词:
煤矿供电变频器电气安全人身触电仿真
Keywords:
coal mine power supply frequency converter electrical safety personal electric shock simulation
分类号:
X934
DOI:
10.11731/j.issn.1673-193x.2016.10.022
文献标志码:
A
摘要:
解释了矿井低压电网系统引入变频器后单相漏电故障电流增大的机理。以人身触电事故为研究对象,建立煤矿井下低压电网变频器系统单相漏电故障的分段线性模型,推导出故障电流的有效值,并经 MATLAB 仿真进行了验证。其分析结果表明,人身触电电流大幅度提高,人身安全水平显著下降。并进一步归纳出矿井低压电网变频器系统单相漏电故障电流的影响因素及一般规律。实验结果验证了理论分析与仿真的正确性。
Abstract:
The mechanism of the phenomenon that the current of single-phase electric leakage fault will increase when introducing the frequency converter into low voltage power grid system of mine was explained. Taking the personal electric shock accident as research object, a piecewise linear model(PLM) of single-phase electric leakage fault in frequency converter system of underground low voltage power grid in coal mine was established. The effective value of fault current was deduced and verified by MATLAB simulation. The results showed that the personal electric shock current increases sharply, and the level of personal safety decreases obviously. The influencing factors and general rules about the current of single-phase electric leakage fault in frequency converter system of low voltage power grid in coal mine were summarized further. The experimental results verified the correctness of theoretical analysis and simulation.

参考文献/References:

[1]胡宏秋. 变频系统漏电分析与研究[J]. 电气传动,2013(8):13-15,37. HU Hongqiu. Analysis and study of frequency conversion system leakage [J]. Electric Drive, 2013(8):13-15,37.
[2]李海洪,王大伟,范征. 变频器引起井下漏电保护系统误动的解决方案[J]. 煤矿安全,2014(9):120-122.LI Haihong, WANG Dawei, FAN Zheng. Solutions of downholeleakage protection systemmisoperationcaused by frequency converter [J]. Safety in Coal Mines,2014(9):120-122.
[3]王宝华,杨占惠. 浅谈变频器原理及在煤矿提升系统中的选用 [J].科技信息, 2008(30):40-41.WANG Baohua, YANG Zhanhui. Introduction to the principle of frequency convertor and its selection in coal mine hoisting system[J] Science and Technology Information, 2008(30): 40-41.
[4]王彦文,高彦. 煤矿供电技术 [M]. 徐州:中国矿业大学出版社, 2013:234-235.
[5]姚秋霞,武贤慧,李斌.VVVF 控制电梯中的漏电流和高次谐波问题及解决对策[J].电气应用,2007,26(6):93-94.YAO Qiuxia, WU Xianhui, LI Bin. Problem and solution of leakage current and high frequency harmonic of elevator controlled by VVVF[J]. Electrical Applications, 2007,26(6):93-94.
[6]Hamman J, Van Der Merwe F S. Voltage harmonics generated byvoltage-fed inverters using PWM natural sampling[J] .IEEETransactions on Power Electronics,1988,3(3):297-302.
[7]王兆安,刘进军. 电力电子技术 [M] 北京:机械工业出版社, 2013:60-61.
[8]陈希有,刘凤春,李冠林. 全桥整流LC滤波电路电感电流连续性判断方法[J]. 电气传动,2011(2):28-31. CHEN Xiyou, LIU Fengchun, LI Guanlin. Judgment method of inductor current continuity of the whole bridge rectifier LC filter circuit[J]. Electric Drive, 2011(2):28-31.
[9]邱关源,罗先觉. 电路 [M] 北京:高等教育出版社,2006: 153.
[10]王彦文,张丙军.移动变电站快速断电安全技术的研究[J]. 煤炭学报,1993,18(4):51-59. WANG Yanwen, ZHANG Bingjun. Study of fast break security technology of mobile transformer substation [J]. International Journal of Coal Science and Technology, 1993,18(4):51-59.
[11]王彦文. 127V供电系统快速断电漏电保护[J]. 煤矿机电,1992(4):12-14,62-63.WANG Yanwen. Fast break leakage protection of 127V power supply[J]. Colliery Mechanical & Electrical Technology, 1992(4):12-14,62-63.
[12]王夺,石勇,许森祥. 基于ATMEGA16单片机的矿用变频器漏电检测系统设计[J]. 煤矿机电,2009(6):13-15.WANG Duo, SHI Yong, XU Senxiang.Leakage detection system design of mine-used frequency-converter based on ATMEGA16 MCU [J]. Colliery Mechanical & Electrical Technology, 2009(6):13-15.
[13]张先华,张磊,孟庆凯,等. 矿用变频器漏电检测系统分析[J]. 科技资讯,2013(27):106,108.ZHANG Xianhua, ZHANG Lei, MENG Qingkai, et al.Analysis of mine-used inverter leakage detection system[J]. Science & Technology Information, 2013(27):106,108.
[14]孙锦,方超,曹亮. 变频器输入电抗器及直流滤波电容器的设计[J]. 应用科技,2014(2):16-20.SUN Jin, FANG Chao, CAO Liang.Design of input reactor and DC filter capacitor of inverter[J]. Applied Science and Technology, 2014(2):16-20.
[15]章建峰. 逆变器死区时间对输出电压的影响分析[J]. 电力电子技术,2007(8):31-33.ZHANG Jianfeng.The analysis of impact to inverter output voltage caused by dead-time[J]. Power Electronics, 2007(8):31-33.

相似文献/References:

[1]高彦,魏可可,霍耀佳,等.具有变频器的矿井低压漏电保护研究[J].中国安全生产科学技术,2019,15(6):127.[doi:10.11731/j.issn.1673-193x.2019.06.020]
 GAO Yan,WEI Keke,HUO Yaojia,et al.Research on mine lowvoltage electric leakage protection with frequency converter[J].JOURNAL OF SAFETY SCIENCE AND TECHNOLOGY,2019,15(10):127.[doi:10.11731/j.issn.1673-193x.2019.06.020]

备注/Memo

备注/Memo:
国家“十二五”科技支撑计划项目(2012BAK041309)
更新日期/Last Update: 2016-11-30