|本期目录/Table of Contents|

[1]王方超,张铎,陈长坤,等.横通道通风对隧道火灾烟气蔓延影响的数值模拟研究*[J].中国安全生产科学技术,2023,19(3):108-114.[doi:10.11731/j.issn.1673-193x.2023.03.016]
 WANG Fangchao,ZHANG Duo,CHEN Changkun,et al.Numerical simulation study on influence of cross-passage ventilation on spread of tunnel fire smoke[J].JOURNAL OF SAFETY SCIENCE AND TECHNOLOGY,2023,19(3):108-114.[doi:10.11731/j.issn.1673-193x.2023.03.016]
点击复制

横通道通风对隧道火灾烟气蔓延影响的数值模拟研究*
分享到:

《中国安全生产科学技术》[ISSN:1673-193X/CN:11-5335/TB]

卷:
19
期数:
2023年3期
页码:
108-114
栏目:
职业安全卫生管理与技术
出版日期:
2023-03-31

文章信息/Info

Title:
Numerical simulation study on influence of cross-passage ventilation on spread of tunnel fire smoke
文章编号:
1673-193X(2023)-03-0108-07
作者:
王方超张铎陈长坤焦伟冰
(1.黄河勘测规划设计研究院有限公司,河南 郑州 450003;
2.中南大学 防灾科学与安全技术研究所,湖南 长沙 410075)
Author(s):
WANG Fangchao ZHANG Duo CHEN Changkun JIAO Weibing
(1.Yellow River Engineering Consulting Co.,Ltd.,Zhengzhou Henan 450003,China;
2.Institute of Disaster Prevention Science and Safety Technology,Central South University,Changsha Hunan 410075,China)
关键词:
横通道火源位置临界风速烟气层高度
Keywords:
cross-passage fire source location critical wind velocity smoke layer height
分类号:
X947
DOI:
10.11731/j.issn.1673-193x.2023.03.016
文献标志码:
A
摘要:
为探究隧道横通道通风对隧道火灾烟气蔓延的影响规律,使用火灾动力学模拟软件FDS,对不同火源位置的横通道临界风速、主隧道温度分布以及烟气层高度进行研究。研究结果表明:在一定火源功率范围内,隧道横通道临界风速与火源功率的1/3次方成正比且火源距横通道越远,临界风速越小;当火源位于交叉口,横通道使用临界风速通风时,隧道内烟气温度明显降低,烟气迅速沉降到2 m以下;当火源距离交叉口10,20 m,横通道通风会加快火源下游烟气沉降,烟气沉降速度随横通道通风速率的增大而增大;当火源位于交叉口时,烟气沉降由横通道通风对烟气的降温作用和涡旋作用共同主导,当火源位于距离交叉口10,20 m时,烟气沉降主要由涡旋作用主导。
Abstract:
In order to explore the influence of cross-passage ventilation on the smoke spread of tunnel fire,the fire dynamics simulation software FDS was used to study the critical wind velocity of cross-passage,the temperature distribution of main tunnel and the height of smoke layer under different fire source locations.The results showed that within a certain range of fire source power,the critical wind velocity of tunnel cross-passage was proportional to 1/3 power of fire source power,and the farther the fire source was away from the cross-passage,the smaller the critical velocity was.When the fire source was located at the intersection and the cross-passage was ventilated with critical wind velocity,the temperature of smoke in the tunnel decreased obviously,but the smoke would quickly settle to below 2 m.When the fire source was 10 m and 20 m away from the intersection,the cross-passage ventilation would accelerate the downstream smoke settlement of fire source,and the smoke settlement velocity increased with the increase of the cross-passage ventilation rate.When the fire source was located at the intersection,the smoke settlement was dominated jointly by the cooling effect of cross-passage ventilation on the smoke and vortex effect,and when the fire source was located 10 m and 20 m away from the intersection,the smoke settlement was mainly dominated by the vortex effect.

参考文献/References:

[1]LI Y Z,INGASON H.Overview of research on fire safety in underground road and railway tunnels[J].Tunnelling and Underground Space Technology,2018,81:568-589.
[2]LI Y Z,INGASON H.Editorial:tunnel fire safety[J].Fire Safety,2018,97:85-86.
[3]赖金星,周慧,程飞.公路隧道火灾事故统计分析及防灾减灾对策 [J].隧道建设,2017,37(4):409-415. LAI Jinxing,ZHOU Hui,CHENG Fei.Statistical analysis of fire accidents in highway tunnels and countermeasures for disaster prevention and reduction[J].Tunnel Construction,2017,37(4):409-415.
[4]胡隆华.隧道火灾烟气蔓延的热物理特性研究[D].合肥:中国科学技术大学,2006.
[5]安全监管总局.晋济高速山西晋城段岩后隧道“3·1”事故调查报告[EB/OL].(2014-06-10)[2022-07-21].http://www.gov.cn/xinwen/2014-06/10/content_2698194.htm.
[6]彭伟,霍然,李元洲.二郎山公路隧道火灾排烟及人车疏散应急方案研究[J].安全与环境学报,2007,7(5):113-116. PENG Wei,HUO Ran,LI Yuanzhou.On scheme of smoking control and evacuation for extremely long highway tunnels [J].Journal of Safety and Environment,2007,7(5):113-116.
[7]李颖臻.含救援站特长隧道火灾特性及烟气控制研究[D].成都:西南交通大学,2007.
[8]LI Y S,ZHANG X L,SUN X P,et al.Maximum temperature of ceiling jet flow in longitudinal ventilated tunnel fires with various distances between fire source and cross-passage [J].Tunnelling and Underground Space Technology,2021,113:103953.
[9]LIU F,HAN J Q,WANG F,et al.Experimental study on the temperature profiles in a naturally ventilated metro tunnel with a transverse cross-passage [J].Tunnelling and Underground Space Technology,2016,106(4):784-795.
[10]ZHANG Y L,CHEN C C,LEI P,et al.A study on buoyancy-driven maximum ceiling gas temperature of T-shaped bifurcated channel-like structure in fire environment [J].International Journal of Thermal Sciences,2013,51(7):246-254.
[11]CHEN C C,NIE Y L,ZHANG Y L,et al.Experimental investigation on the influence of ramp slope on fire behaviors in a bifurcated tunnel [J].Tunnelling and Underground Space Technology,2020,104:103522.
[12]LI Y Z,LEI B,INGASON H.Theoretical and experimental study of critical velocity for smoke control in a tunnel cross-passage[J].Fire Technology,2013(49):435-449.
[13]FENG S,LI Y F,HOU Y S,et al.Study on the critical velocity for smoke control in a subway tunnel cross-passage [J].Tunnelling and Underground Space Technology,2020,10(11):67-79.
[14]HOU Y S,LI Y F,ZHANG C.Influence of train location on smoke control in tunnel cross-passage [J].Procedia Engineering,2016,21(13):567-573.
[15]HUANG Y B,LI Y F,LI J X.Experimental study on the temperature longitudinal distribution induced by a branched tunnel fire [J].International Journal of Thermal Sciences,2021,17(21):110-121.
[16]HUANG Y B,LI Y F,LI J M.Modelling and experimental investigation of critical velocity and driving force for preventing smoke backlayering in a branched tunnel fire [J].Tunnelling and Underground Space Technology,2020,25(10):110-118.
[17]姜学鹏,何超,郭辉.Y型合流分岔隧道临界风速计算模型[J].安全与环境学报,2019,19(1):210-216. JIANG Xuepeng,HE Chao,GUO Hui.A model for calculating the critical velocity of letter Y shape joined bifurcation tunne [J].Journal of Safety and Environment,2019,19(1):210-216.
[18]郭洪雨,田伟,刘佳.带平行导洞的公路隧道合理排烟策略[J].隧道及地下工程灾害防治,2021,3(2):70-76. GUO Hongyu,TIAN Wei,LIU Jia.Reasonable smoke exhaust strategy of highway tunnel with a parallel pilot tube [J].Hazard Control in Tunnelling and Underground Engineering,2021,3(2):70-76.
[19]中华人民共和国交通运输部.公路隧道设计规范 第一册 土建工程:JTG 3370.1—2018[S].北京:人民交通出版社股份有限公司,2018.
[20]中华人民共和国交通运输部.公路隧道通风设计细则:JTG/T D70/2-02—2014[S].北京:人民交通出版社股份有限公司,2014.
[21]HE Y,FERNANDO A,LUO M.Determination of interface height from measured parameter profile in enclosure fire experiment[J].Fire Safety Journal,1998,31(1):19-38.
[22]LI Y Z,LEI B,INGASON H.Study of critical velocity and backlayering length in longitudinally ventilated tunnel fires[J].Fire Safety Journal,2010,45(10):361-370.

相似文献/References:

[1]李建,史聪灵,李昀松,等.隧道与横通道交叉角对火灾烟气蔓延影响机制研究[J].中国安全生产科学技术,2020,16(7):36.[doi:10.11731/j.issn.1673-193x.2020.07.006]
 LI Jian,SHI Congling,LI Yunsong,et al.Research on influence mechanism of crossing angle between tunnel and cross passage on fire smoke spread[J].JOURNAL OF SAFETY SCIENCE AND TECHNOLOGY,2020,16(3):36.[doi:10.11731/j.issn.1673-193x.2020.07.006]
[2]李智胜,蒋浩锴,高云骥,等.分岔隧道火灾烟气流动特性研究*[J].中国安全生产科学技术,2021,17(5):118.[doi:10.11731/j.issn.1673-193x.2021.05.018]
 LI Zhisheng,JIANG Haokai,GAO Yunji,et al.Study on flow characteristics of fire smoke in bifurcated tunnel[J].JOURNAL OF SAFETY SCIENCE AND TECHNOLOGY,2021,17(3):118.[doi:10.11731/j.issn.1673-193x.2021.05.018]
[3]张嬿妮,杨丹,温心宇,等.火源位置对浮法玻璃热破裂行为规律影响研究*[J].中国安全生产科学技术,2021,17(8):143.[doi:10.11731/j.issn.1673-193x.2021.08.022]
 ZHANG Yanni,Yang Dan,WEN Xinyu,et al.Study on influence of fire source location on thermal fracture behavioral laws of float glass[J].JOURNAL OF SAFETY SCIENCE AND TECHNOLOGY,2021,17(3):143.[doi:10.11731/j.issn.1673-193x.2021.08.022]
[4]陈长坤,焦伟冰,雷鹏,等.分岔隧道火灾火源位置对临界风速影响的数值模拟分析*[J].中国安全生产科学技术,2022,18(3):93.[doi:10.11731/j.issn.1673-193x.2022.03.014]
 CHEN Changkun,JIAO Weibing,LEI Peng,et al.Numerical simulation analysis on influence of fire source position on critical wind velocity of bifurcated tunnel fire[J].JOURNAL OF SAFETY SCIENCE AND TECHNOLOGY,2022,18(3):93.[doi:10.11731/j.issn.1673-193x.2022.03.014]
[5]方祥,任飞,李建,等.不同隧道坡度与车厢火灾位置情况下烟气蔓延特性研究*[J].中国安全生产科学技术,2022,18(9):35.[doi:10.11731/j.issn.1673-193x.2022.09.005]
 FANG Xiang,REN Fei,LI Jian,et al.Study on smoke spread characteristics under different tunnel slopes and car fire locations[J].JOURNAL OF SAFETY SCIENCE AND TECHNOLOGY,2022,18(3):35.[doi:10.11731/j.issn.1673-193x.2022.09.005]
[6]李宇辉,费瑞振,等.考虑分岔角度和火源位置的地铁分岔隧道火灾临界风速研究[J].中国安全生产科学技术,2024,20(1):100.[doi:10.11731/j.issn.1673-193x.2024.01.015]
 LI Yuhui,FEI Ruizhen,QIAN Shijia.Study on critical wind velocity of subway bifurcated tunnel fire considering bifurcation angle and fire source location[J].JOURNAL OF SAFETY SCIENCE AND TECHNOLOGY,2024,20(3):100.[doi:10.11731/j.issn.1673-193x.2024.01.015]

备注/Memo

备注/Memo:
收稿日期: 2022-07-21
* 基金项目: 重载交通单洞双向特长隧道及隧道群建设与营运安全关键技术(2021KY027)
作者简介: 王方超,硕士,高级工程师,主要研究方向为公路工程。
更新日期/Last Update: 2023-04-12