[1]RAIMUNDO A M,FIGUEIREDO A R.Personal protective clothing and safety of firefighters near a high intensity fire front[J].Fire Safety Journal,2009,44(4):514-521.
[2]International Organization for Standardization.Textiles—physiological effects—measurement of thermal and evaporative resistance under steady-state conditions (sweating guarded-hotplate test):ISO 11092—2014[S].Switzerland:European Committee for Standardization,2014.
[3]American Society for Testing and Materials.Standard test method for measuring the thermal insulation of clothing using a heated manikin:ASTM F1291—16[S].West Conshohocken,PA:American Society for Testing Materials,2016.
[4]American Society for Testing Materials.Standard test method for measuring the evaporative resistance of clothing using a sweating manikin:ASTM F2370—16[S].West Conshohocken,PA:American Society for Testing Materials,2016.
[5]POTTER A W,GONZALEZ J A,KARIS A J,et al.Biophysical assessment and predicted thermophysiologic effects of body armor[J].Plos One,2015,10(7):e0132698.
[6]NIELSEN R,OLESEN B W,FANGER P O.Effect of physical activity and air velocity on the thermal insulation of clothing[J].Ergonomics,1985,28(12):1617-1631.
[7]HAVENITH G,NILSSON H O.Correction of clothing insulation for movement and wind effects,a meta-analysis[J].European Journal of Applied Physiology,2004,92(6):636-640.
[8]丁殷佳,王利君.风速对单双层织物热阻的影响[J].毛纺科技,2016,44(3):1-5.
DING Yinjia,WANG Lijun.Influence of the wind speed on thermal resistance of singlelayer and doublelayer fabrics [J].Wool Textile Journal,2016,44 (3):1-5.
[9]李利君,宋国文,李睿,等.消防员防护服面料的热湿舒适性[J].纺织学报,2017,38(3):122-125.
LI Lijun,SONG Guowen,LI Rui,et al.Heat-moisture comfort of firefighter’s protective clothing materials[J].Journal of Textile Research,2017,38 (3):122-125.
[10]DING D.Characterizing the performance of a single-layer fabric system through a heat and mass transfer model[D].Edmonton:University of Alberta,2010.
[11]American Society for Testing Materials.Standard test method for thermal and evaporative resistance of clothing materialsusing a sweating hot plate:ASTM F1868—17[S].West Conshohocken,PA:American Society for Testing Materials,2017.
[12]HAVENITH G,HEUS R,LOTENS W A.Resultant clothing insulation:a function of body movement,posture,wind,clothing fit and ensemble thickness[J].Ergonomics,1990,33(1):67-84.
[13]MORRISSEY M,ROSSI R.The effect of wind,body movement and garment adjustments on the effective thermal insulation of clothing with low and high air permeability insulation[J].Textile Research Journal,2013,84(6):583-592.
[14]NIELSEN R,OLESEN B W,FANGER P O.Effect of physical activity and air velocity on the thermal insulation of clothing[J].Ergonomics,1985,28:1617-1631.
[15]FAN J T,KEIGHLEY J H.An investigation on the effects of body motion,clothing design and environmental conditions on the clothing thermal insulation by using a fabric manikin[J].International Journal of Clothing Science & Technology,1991,3(5):6-13.
[16]于瑶,钱晓明,范金土.风速与步速对服装表面空气层热阻的影响[J].纺织学报,2009,30(8):107-112.
YU Yao,QIAN Xiaoming,FAN Jintu.Effects of air velocity and walking speed on thermal insulation of clothing[J].Journal of Textile Research,2009,30 (8):107-112.
[17]陈益松,张聪聪.纺织面料热阻和湿阻的回归测量法[J].东华大学学报(自然科学版),2018,44(5):742-748.
CHEN Yisong,ZHANG Congcong.Fabric thermal and evaporative resistance’s regression measurement method[J].Journal of Donghua University (Natural Science),2018,44 (5):742-748.
[18]CHEN Y S,FAN J T,QIAN X,et al.Effect of garment fit on thermal insulation and evaporative resistance[J].Textile Research Journal,2004,74(8),742-748.