|本期目录/Table of Contents|

[1]任常兴,赵文胜,张琰,等.R290制冷剂惰化燃爆特性实验研究[J].中国安全生产科学技术,2017,13(8):49-54.[doi:10.11731/j.issn.1673-193x.2017.08.008]
 REN Changxing,ZHAO Wensheng,ZHANG Yan,et al.Experimental study on combustion and explosion characteristics of R290 refrigerant after inerting[J].JOURNAL OF SAFETY SCIENCE AND TECHNOLOGY,2017,13(8):49-54.[doi:10.11731/j.issn.1673-193x.2017.08.008]
点击复制

R290制冷剂惰化燃爆特性实验研究
分享到:

《中国安全生产科学技术》[ISSN:1673-193X/CN:11-5335/TB]

卷:
13
期数:
2017年8期
页码:
49-54
栏目:
学术论著
出版日期:
2017-08-31

文章信息/Info

Title:
Experimental study on combustion and explosion characteristics of R290 refrigerant after inerting
文章编号:
1673-193X(2017)-08-0049-06
作者:
任常兴1赵文胜2张琰1王丽2
(1.公安部天津消防研究所,天津 300381;2.天津理工大学 环境科学与安全工程学院,天津 300384)
Author(s):
REN Changxing1 ZHAO Wensheng2 ZHANG Yan1 WANG Li2
(1. Tianjin Fire Research Institute of MPS, Tianjin 300381, China; 2. School of Environmental Science and Safety Engineering, Tianjin University of Technology, Tianjin 300384, China)
关键词:
R290极限氧浓度三元图惰化效果爆炸极限
Keywords:
R290 R290 limiting oxygen concentration (LOC) ternary diagram inerting effect explosion limits
分类号:
X936
DOI:
10.11731/j.issn.1673-193x.2017.08.008
文献标志码:
A
摘要:
为了研究R290制冷剂惰化燃爆特性,采用带搅拌功能和氧浓度在线测定的20L球试验装置,对R290制冷剂进行了极限氧浓度测定。实验测定了丙烷在CO2和N2惰化气氛中的爆炸极限及极限空气浓度LAC,确定丙烷的极限氧浓度LOC;采用三元图爆炸区、丙烷-O2二维图爆炸区和ASTM标准分布图分析了混合气体爆炸区边界的燃爆特征,给出了极限氧浓度的确定方法和边界爆炸压力分布规律。实验结果表明:常温常压下R290的爆炸极限为2.1%~9.6%,CO2惰化气氛中的极限氧浓度为13.3%,对应的丙烷浓度为3.3%;N2惰化气氛中的极限氧浓度为10.8%,对应的丙烷浓度为2.7%。通过对比分析不同CO2和N2浓度下的爆炸区分布特征,表明CO2对丙烷的惰化效果要优于N2,以氮气和二氧化氮体积分数比为1∶2测试惰化气氛保护能力,惰化效果介于同浓度单种惰性气体之间。
Abstract:
To study the combustion and explosion characteristics of R290 refrigerant after inerting, the measurement of limiting oxygen concentration (LOC) on R290 refrigerant was carried out by using the spherical 20L chamber with the stirring function and on-line measurement of oxygen concentration. The explosion limits and limiting air concentration (LAC) of propane in the inerting atmosphere of CO2 and N2 were measured, and the LOC of propane was determined. The combustion and explosion characteristics in the explosion zone boundary of the gas mixture were analyzed by using the ternary diagram explosion zone, propane-oxygen two-dimensional diagram explosion zone and ASTM standard distribution diagram, and the determination method of LOC and the distribution laws of boundary explosion pressure were presented. The results showed that the explosion limits of R290 under normal temperature and pressure was from 2.1% (v/v) to 9.6% (v/v), and the LOC in the inerting atmosphere of CO2 was 13.3%, with the corresponding propane concentration of 3.3% (v/v). The LOC in the inerting atmosphere of N2 was 10.8%, with the corresponding propane concentration of 2.7% (v/v). Through comparing and analyzing the distribution characteristics of explosion zone under different concentration of CO2 and N2, it showed that the inerting effect of CO2 for propane was better than N2. Furthermore, the inerting effect was between the single inert gas with the same concentration when testing the protection capability of inerting atmosphere with the volume fraction ratio of N2 and CO2 as 1∶2.

参考文献/References:

[1]European standard.Determination of the limiting oxygen concentration (LOC) for gases and vapours: EN 14756-2007[S].Berlin:European committee for standardization,2006.
[2]American society for testing and materials.Standard test methods for limiting oxygen (oxidant) concentration in gases and vapors: ASTM E2079-07(2013)[S].West Conshohocken, United States: ASTM international,2013.
[3]Wang Z R, Ni L, Liu X, et al. Effects of N 2 /CO2 on explosion characteristics of methane and air mixture[J]. Journal of Loss Prevention in the Process Industries, 2014, 31:10-15.
[4]Zlochower I A, Green G M. The limiting oxygen concentration and flammability limits of gases and gas mixtures[J]. Journal of Loss Prevention in the Process Industries, 2009, 22(4):499-505.
[5]Razus D, Molnarne M. Limiting oxygen concentration evaluation in flammable gaseous mixtures by means of calculated adiabatic flame temperatures[J]. Chemical Engineering & Processing Process Intensification, 2004, 43(6):775-784.
[6]Jensen J W, Walsh D F, Mines U S B O. Flammability Characteristics of Combustible Gases and Vapors[J]. Synthetic Fuels, 1964:918-924.
[7]KL Cashdollar,IA Zlochower,GM Green and et.al.Flammability of methane, propane, and hydrogen gases[J].Journal of Loss Prevention in the Process Industries 2000 ,13(3):327-340
[8]Schoor F V D, Norman F, Vandermeiren K, et al. Flammability limits, limiting oxygen concentration and minimum inert gas/combustible ratio of H2/CO/N2/air mixtures[J]. International Journal of Hydrogen Energy, 2009, 34(4):2069-2075.
[9]任常兴, 张发, 李晋. 不同氧浓度条件下制冷剂R290燃爆特性[J]. 消防科学与技术, 2016(3):298-301. REN Changxing, ZHANG Fa, LI Jin. Combustion characteristics of refrigerant R290 under different oxygen concentration conditions[J].Fire science and technology, 2016(3):298-301.
[10]任常兴, 张欣, 慕洋洋,等. 可燃气体和混合气极限氧浓度实验研究[J].消防科学与技术, 2017, 36(2):156-159. REN Changxing, ZHANG Xin, MU Yangyang, et al. Experimental study on the oxygen concentration of combustible gas and mixed gas Limited[J]. Fire science and technology, 2017, 36(2):156-159.
[11]李恩田,谢磊,王树立. 浮顶油罐油气惰化防火防爆实验研究[J]. 中国安全生产科学技术,2011,7(11):68-71. LI Entian, XIE Lei, WANG Shuli. Experimental research on vapourdeactivation for fire and explosion prevention in floating-roof tank[J]. Journal of safety science and technology,2011,7(11):68-71.
[12]刘益东, 皮涛. N2,H2,O2爆炸极限三元图的研究及其应用[J].煤气与热力, 1992(4):43-46. LIU Yidong, PI Tao, Research and application of explosion limit three element diagram of N2, H2, O2mixture [J].Gas and heat, 1992(4):43-46.
[13]李伟用. 氮气惰化技术在煤矿灭火中的应用[J]. 内蒙古煤炭经济, 1996:51-51. LI Weiyong.Application of nitrogen gasification technology in coal mine fire extinguishing[J].Inner Mongolia coal economy, 1996:51-51.
[14]郝朝瑜,王继仁,黄戈,等.基于惰化降温耦合作用的采空区低温CO2注入位置研究[J].中国安全生产科学技术,2015,11(9):17-23. HAO Chaoyu, WANG Jiren, HUANG Ge, et al. Study on inject position of low temperature CO2 in gob based on coupling effect of inerting cooling[J].Journal of safety science and technology, 2015,11(9):17-23.
[15]National Fire Protection Association.standard on explosion protection by deflagration venting:NFPA 68-2013[S]. Batterymarch park, Quincy:NFPA,2013.