|本期目录/Table of Contents|

[1]刘健,杨仲江,卢慧慧.外浮顶油罐雷击起火概率计[J].中国安全生产科学技术,2016,12(4):45-49.[doi:10.11731/j.issn.1673-193x.2016.04.009]
 LIU Jian,YANG Zhongjiang,LU Huihui.Calculation on probability of fire caused by lightning for external floating roof oil tanks[J].JOURNAL OF SAFETY SCIENCE AND TECHNOLOGY,2016,12(4):45-49.[doi:10.11731/j.issn.1673-193x.2016.04.009]
点击复制

外浮顶油罐雷击起火概率计
分享到:

《中国安全生产科学技术》[ISSN:1673-193X/CN:11-5335/TB]

卷:
12
期数:
2016年4期
页码:
45-49
栏目:
学术论著
出版日期:
2016-04-30

文章信息/Info

Title:
Calculation on probability of fire caused by lightning for external floating roof oil tanks
作者:
刘健12杨仲江12卢慧慧12
1.南京信息工程大学 中国气象局气溶胶-云-降水重点开放实验室,江苏 南京 210044;
2.南京信息工程大学 大气物理学院,江苏 南京 210044)
Author(s):
LIU Jian12 YANG Zhongjiang12 LU Huihui12
(1. Key Laboratory for Aerosol-Cloud-Precipitation of China Meteorological Administration, Nanjing University of Information Science and Technology, Nanjing Jiangsu 210044, China;
2. School of Atmospheric Physics, Nanjing University of Information Science and Technology, Nanjing Jiangsu 210044, China)
关键词:
雷电外浮顶油罐雷击概率蒙特卡洛方法火花放电
Keywords:
lightning external floating roof oil tanks lightning strike probability Monte Carlo method spark discharge
分类号:
X915.5
DOI:
10.11731/j.issn.1673-193x.2016.04.009
文献标志码:
A
摘要:
大型外浮顶储罐多次发生雷击起火事故,因此对其安全性做出客观评价,计算雷击起火概率现实意义重大。通过分析雷电对外浮顶油罐的危害方式,利用蒙特卡洛方法结合电气几何模型计算外浮顶油罐年雷击率。分析采用导静电线和可伸缩接地装置(RGA)的防护效果差别。最后计算安装可伸缩接地装置后油罐遭受雷击产生火花放电的年事故率。计算结果表明:年雷击率随着油罐直径和罐壁高度的增大而增加;采用可伸缩接地装置的防护效果明显优于传统导静电线;安装多个可伸缩接地装置可以明显降低产生火花的概率和年事故率。两个RGA就可以将油罐遭受雷击产生火花放电的年事故率降至10-5以下。
Abstract:
Fire accidents caused by lightning strike on large external floating roof (EFR) oil tanks have occurred for many times, so it is practically significant to evaluate the safety objectively and calculate the probability of fire caused by lightning. The harm modes of lightning on oil tanks were presented. The annual incidence of lightning strike for external floating roof oil tanks were calculated by means of Monte Carlo method combined with electro-geometric model (EGM). The difference in protection effects of conventional electrostatic conductors and retractable grounding assemblies (RGA) were analyzed. The annual accident rates of spark discharge by lightning on oil tanks installing RGAs were discussed. The results showed that the annual incidence of lightning strike increase with the increasing diameters and heights of oil tanks. The protection effect by using RGA is better than that of conventional electrostatic conductors. The probability and annual accident rates of spark discharge can be significantly decreased when multiple RGAs are installed. The annual accident rates of spark discharge by lightning on oil tanks can be reduced to 10-5 when only two RGAs are installed.

参考文献/References:

[1]G. Antonioni, S. Bonvicini, G. Spadoni, et al. Development of a framework for the risk assessment of Na-Tech accidental events [J]. Reliability Engineering and System Safety, 2009, 94(9): 1442-1450.
[2]刘晅亚, 张清林, 秘义行, 等. 大型石油储罐区火灾风险预测预警技术研究[J]. 消防科学与技术, 2012(2): 192-196. LIU Xuanya, ZHANG Qinglin, BI Yixing, et al. Study of large oil storage tank zone fire risk forecast and early warning technology [J]. Fire Science and Technology, 2012(2): 192-196.
[3]刘宝全, 刘全桢, 刘娟, 等. 大型浮顶储油罐雷击事故分析及防范对策[J]. 安全、健康和环境, 2012, 12(1): 10-13. LIU Baoquan, LIU Quanzhen, LIU Juan, et al. Analysis and countermeasure of lightning stroke accident for large-scale oil tanks [J]. Safety Health & Environment, 2012, 12(1): 10-13.
[4]刘娟, 刘全桢, 刘宝全, 等. 大型浮顶储罐雷击火灾事故机理分析[J]. 中国安全生产科学技术, 2013, 9(1): 108-112. LIU Juan, LIU Quanzhen, LIU Baoquan, et al. Mechanism analysis on lightning fire accident of large floating roof storage tank [J]. Journal of Safety Science and Technology, 2013, 9(1): 108-112.
[5]郝俊琦, 李琳, 王平. 基于蒙特卡罗法的超高压输电线路绕击跳闸率的计算[J]. 华北电力大学学报, 2012, 39(5): 35-41. HAO Junqi, LI Lin, WANG Ping. Calculation for shielding failure trip-out rate of EHV transmission line based on monte carlo method [J]. Journal of North China Electric Power University, 2012, 39(5): 35-41.
[6]A. Borghetti, V. Cozzani, C. Mazzetti, et al. Monte Carlo based lightning risk assessment in oil plant tank farms [C]. ICLP 2010, Cagliari, July 16-19, 2010.
[7]IEEE Std. 1410-2010. IEEE guide for improving the lightning performance of electric power overhead distribution lines [S].
[8]GB 50064-2014, 交流电气装置的过电压保护和绝缘配合设计规范[S].2014.
[9]IEC 62305-2, Protection Against Lightning Part 2: Risk management [S].
[10]李征西, 徐思文. 油品储运设计手册[M]. 北京: 石油工业出版社, 1997.
[11]API RP545-2009, Recommended practice for lightning protection of aboveground storage tanks for flammable or combustible liquids [S].
[12]GB 15599-2009, 石油与石油设施雷电安全规范[S].2009.
[13]刘轶, 严伟. 射频电路设计原理[M]. 北京: 清华大学出版社, 2014.
[14]GB 50057-2010, 建筑物防雷设计规范[S].2010.
[15]任晓明, 傅正财, 刘全桢, 等. 大型浮顶油罐直击雷防护实验分析[J]. 高电压技术, 2011, 37(4): 867-872. REN Xiaoming, FU Zhengcai, LIU Quanzhen, et al. Experimental analysis of direct lightning protection for floating roof oil tanks [J]. High Voltage Engineering, 2011, 37(4): 867-872.
[16]Hu H Y, Liu Q Z. Research on lightning sparks discharge and protection measures of large floating roof tank [C]. ICLP 2012, Vienna, Sept. 2-7, 2012.

相似文献/References:

[1]刘强,纪新建.浅谈加油加气站的防雷防静电安全检测*[J].中国安全生产科学技术,2009,5(5):144.
 LIU Qiang,JI Xin jian.Safety checking on the lightning and static electricity of automobile gasoline and gas filling station[J].JOURNAL OF SAFETY SCIENCE AND TECHNOLOGY,2009,5(4):144.

备注/Memo

备注/Memo:
国家自然科学基金项目(41175003),江苏高校优势学科建设工程资助项目(PADA)
更新日期/Last Update: 2016-05-05