|本期目录/Table of Contents|

[1]张雪艳,王忠旭,李玉珍,等.KN95颗粒物防护口罩适合性与头面部尺寸关系研究[J].中国安全生产科学技术,2015,11(2):154-159.[doi:10.11731/j.issn.1673-193x.2015.02.025]
 ZHANG Xue-yan,WANG Zhong-xu,LI Yu-zhen,et al.Study on relationship between fitness of KN95 particulate respirators and facial dimensions[J].JOURNAL OF SAFETY SCIENCE AND TECHNOLOGY,2015,11(2):154-159.[doi:10.11731/j.issn.1673-193x.2015.02.025]
点击复制

KN95颗粒物防护口罩适合性与头面部尺寸关系研究
分享到:

《中国安全生产科学技术》[ISSN:1673-193X/CN:11-5335/TB]

卷:
11
期数:
2015年2期
页码:
154-159
栏目:
职业安全卫生管理与技术
出版日期:
2015-02-28

文章信息/Info

Title:
Study on relationship between fitness of KN95 particulate respirators and facial dimensions
作者:
张雪艳王忠旭李玉珍贾宁顾永恩赵霞
(中国疾病预防控制中心 职业卫生与中毒控制所,北京100050)
Author(s):
ZHANG Xue-yan WANG Zhong-xu LI Yu-zhen JIA Ning GU Yong-en ZHAO Xia
(National Institute of Occupational Health and Poison Control, 100050 Beijing, China)
关键词:
颗粒物防护口罩适合性头面部尺寸定量适合性检验
Keywords:
particulate respirators fitness facial dimensions quantitative fitness test
分类号:
X96
DOI:
10.11731/j.issn.1673-193x.2015.02.025
文献标志码:
A
摘要:
测量两种KN95颗粒物防护口罩的适合性和人体头面部尺寸,分析影响口罩适合性的人体尺寸因素。选择80名受试对象,使用弯角规和直角规进行头面部尺寸测量。受试者分别佩戴3M 8210、3M 8210v颗粒物防护口罩,使用TSI 8038进行定量适合性检验。两种口罩的适合性检验通过率无差异(P>0.05),通过率无性别差异(P>0.05)。男性鼻宽对3M 8210的适合性有影响(P<0.05),女性面宽和两耳屏点间颌下弧长对3M 8210v的适合性有影响(P<0.05)。面宽和鼻宽可作为初步选择颗粒物防护口罩的参考指标,但仍需经过定量适合性检验。
Abstract:
The fitness of two KN95 particulate respirators and the facial dimensions of human body were measured to analyze the factors of human body dimension affecting the fitness of respirators. The facial dimensions of 80 test subjects were measured by bending angle gauge and right angle gauge. 3M 8210 and 3M 8210v particulate respirators were worn by the same subject respectively, and the quantitative fitness test was conducted by TSI 8038. It showed that there was no significant difference between the passing rate of two respirators(P>0.05). Furthermore, no gender difference was observed for passing rate(P>0.05). Nose breadth influenced the fitness of 3M 8210 respirator for males(P<0.05), while bizygomatic breadth and bitragion-submandibuler arc influenced the fitness of 3M 8210v respirator for females(P<0.05). Bizygomatic breadth and nose breadth could be used as the reference indexes to choose the proper respirators preliminarily, but the quantitative fitness test was still required.

参考文献/References:

[1]Centers for Disease Control and Prevention. Laboratory performance evaluation of KN95 filtering facepiece respirators [R]. Morb Mortal Wkly Rep,1996,47 :1045-1049
[2]Derrick JL, Chan YF, Gomersall CD, et al. Predictive value of the user seal check in determining half-face respirator fit[J]. J Hosp Infect,2005, 59 :152-155
[3]Tablan OC, Anderson LJ, Besser R, et al. Healthcare Infection Control Practices Advisory Committee. Guidelines for preventing health-care-associated pneumonia, 2003: recommendations of CDC and the Healthcare Infection Control Practices Advisory Committee[R]. MMWR Recomm Rep,2004,26(53(RR-3)):1-36
[4]Occupational Safety & Health Administration. Personal protective equipment. 3151-12R[S]. US Department of Labor Regulations: OSHA; 2003
[5]TSI Incorporated. Portacount Pro 8030 and Portacount Pro+ 8038 Respirator Fit Testers: operation and service manual. Minnesota: TSI Incorporated; 2008-2011
[6]程文娟,余艳艳,余丹,等. 自吸过滤式防尘口罩适合性与头面部尺寸关系分析[J].中华劳动卫生与职业病杂志,2012,30(5):352-355 CHENG Wen-juan,YU Yan-yan,YU Dan, et al. The relationship between fit characteristics of two kinds of self-inhalation air-purifying dust respirators and head-face dimensions of subjects[J].Chin J Ind HygOccupDis,2012, 30(5):352-355
[7]J.L. Derrick, Y.F. Chan, C.D. Gomersall,et al. Predictive value of the user seal check in determining half-face respirator fit[J]. J Hosp Infect, 2005,(59):152-155
[8]S.C. Lam, J.K.L. Lee, S.Y. Yau, et al. Sensitivity and speci ficity of the user-seal-check in determining the fit of KN95 respirators[J]. J Hosp Infect,2011, (77): 252-256
[9]Han DH. Fit factors for quarter masks and facial size categories[J]. Ann Occup Hyg, 2000, 44 (3): 227-34
[10]Adri Spies, Kerry S Wilson, Robert Ferrie. Respirator fit of a medium mask on a group of South Africans: a cross-sectional study[J]. Environ Health,2011, (10): 17-23
[11]Du L,Zhuang Z, Guan H,et al. Head-and-face anthropometric survey of Chinese workers. Ann Occup Hyg[J].2008,52 (8):773-782
[12]Zhuang, Z., C.C. Coffey, R.B. Ann. The effect of subject characteristics and respirator features on respirator fit[J]. J Occup Environ Hyg,2005,(2):641-649
[13]R. Kent Oestenstad, Leshan J. Elliott, T. Mark Beasley. The Effect of Gender and Respirator Brand on the Association of Respirator Fit with Facial Dimensions[J]. J Occup Environ Hyg,2007,4 (12):923-930
[14]Oestenstad RK,Dillion HK,Perkins LL. Distribution of face seal leak sites on a half-mask respirator and their association with facial dimensions[J]. Am Ind Hyg Assoc J,1990,51 (5):285-290

相似文献/References:

[1]刘锦艳,孙辰晨,朱晓俊.自吸过滤式防颗粒物呼吸器防护性能标准对比分析*[J].中国安全生产科学技术,2023,19(8):87.[doi:10.11731/j.issn.1673-193x.2023.08.013]
 LIU Jinyan,SUN Chenchen,ZHU Xiaojun.Comparitive analysis of standards for protection performance of non-powered air-purifying particle respirator[J].JOURNAL OF SAFETY SCIENCE AND TECHNOLOGY,2023,19(2):87.[doi:10.11731/j.issn.1673-193x.2023.08.013]

备注/Memo

备注/Memo:
北京市自然科学基金青年项目(7144233)
更新日期/Last Update: 2015-02-28