|本期目录/Table of Contents|

[1]颜丽,文一蔚.某大型商场性能化防火设计评估[J].中国安全生产科学技术,2013,9(12):138-142.[doi:10.11731/j.issn.1673-193x.2013.12.023]
 YAN Li,WEN Yi wei.A performancebased fire protection analysis of a large shopping mall [J].JOURNAL OF SAFETY SCIENCE AND TECHNOLOGY,2013,9(12):138-142.[doi:10.11731/j.issn.1673-193x.2013.12.023]
点击复制

某大型商场性能化防火设计评估
分享到:

《中国安全生产科学技术》[ISSN:1673-193X/CN:11-5335/TB]

卷:
9
期数:
2013年12期
页码:
138-142
栏目:
职业安全卫生管理与技术
出版日期:
2013-12-30

文章信息/Info

Title:
A performancebased fire protection analysis of a large shopping mall 
作者:
颜丽1 文一蔚2
(1重庆市消防总队,重庆401121;2重庆市建工集团 设计研究院,重庆401147)
Author(s):
YAN Li WEN Yiwei
(1. Chongqing Fire Brigade, Chongqing 401121, China; 2. Design and Research Institute, Chongqing Construction Engineering Group, Chongqing 401147, China)
关键词:
性能化防火设计火灾荷载安全疏散时间大型商场
Keywords:
performancebased fire protection design fire loads ASET large shopping mall
分类号:
X932
DOI:
10.11731/j.issn.1673-193x.2013.12.023
文献标志码:
A
摘要:
利用FDS、Pathfinder软件对某大型商业建筑防火安全性能进行评估,实测火灾荷载数据,探究发生火灾情况下,能否满足人员安全疏散的要求。评估发现,大型商业建筑在采用一系列消防安全措施后,在消防设施正常工作情况下,疏散宽度可在现行规范规定基础上作适当放宽。
Abstract:
The performance of fire protection safety in a large commercial building was analyzed by FDS and Pathfinder software. The datas of fire load were measured on\|site, so as to explore whether it can meet the requirements of safety evacuation for people in fire condition. It showed that: after applying a series of fire safety measures, when the fire protection facilities are under normal operating conditions, the evacuation width of the large commericial building can be appropriately relaxed on the bisis of existing standard.

参考文献/References:

[1]杜兰萍. 基于性能化的大尺度公共建筑防火策略研究[D].天津:天津大学,2007 DU Lanping. Based on performance of large public buildings fire protection strategy study [D]. Tianjin: Tianjin University, 2007
[2]范维澄,孙金华,陆守香.火灾风险评估方法学[M].北京:科学出版社,2004
[3]霍然,胡源,李元洲. 建筑火灾安全工程导论[M].合肥:中国科学技术大学出版社,1999
[4]姚斌,刘乃安,李元洲.论性能化防火分析中的安全疏散时间判据[J].火灾科学,2003,12(2):7983 YAO Bin, LIU Naian, LI Yuanzhou. On the criteria of safety egress time for performancebased fire protection analysis[J]. Fire Safety Science, 2003, 12(2): 7983
[5]熊筠,王经伟.某地下商场防火分区的性能化分析[J].中国西部科技, 2007, (10):6465 XIONG Jun, WANG Jingwei. An performance analysis about an underground store's fire compartmentation[J]. Science and Technology of West China, 2007, (10):6465
[6]唐永,邢志祥.高层建筑火灾安全疏散研究述评[J].中国安全生产科学技术,2011,7(10):5659 TANG Yong, XING Zhixiang. Review on study of evacuation in highrise bulding fire[J]. Journal of Safety Science and Technology, 2011,7(10):5659
[7]吕辰, 刘泽功, 周建, 等. 建筑火灾时期人员密度对安全疏散时间的影响分析[J].中国安全生产科学技术,2013,9(7):4448 LV Chen,LIU Zhegong,ZHOU Jian,et al.Analysis on influence of personal density on evacuation time in building fire[J]. Journal of Safety Science and Technology, 2013, 9(7):4448
[8]亓延军,陈兵,石龙,等.基于性能化设计的某大型游乐场人员疏散研究[J].中国安全生产科学技术,2010,6(1):8386 QI Yanjun,CHEN Bing,SHI Long,et al.Study on evacuation of large carnie based on performancebased design[J]. Journal of Safety Science and Technology, 2010, 6(1):8386〖FL)〖HJ〖HT〖ST〖WT〖LM

相似文献/References:

[1]马千里,倪照鹏,黄鑫,等.大型商业建筑室内步行街商铺火灾荷载调查研究[J].中国安全生产科学技术,2011,7(4):52.
 MA Qian-li,NI Zhao-peng,HUANG Xin,et al.Survey research on fire load of the shops along the walking street inside the large commercial center[J].JOURNAL OF SAFETY SCIENCE AND TECHNOLOGY,2011,7(12):52.
[2]吴立志,李莉,孙宽,等.KTV娱乐场所火灾荷载调查与统计分析研究[J].中国安全生产科学技术,2012,8(7):123.
 WU Li zhi,LI Li,SUN Kuan,et al.Survey and statistical analysis on fire loads of KTV[J].JOURNAL OF SAFETY SCIENCE AND TECHNOLOGY,2012,8(12):123.
[3]黄〓颖,罗〓静,崔〓飞,等.云南省高校学生宿舍火灾荷载的调查与分析[J].中国安全生产科学技术,2012,8(9):133.
 HUANG Ying,LUO Jing,CUI Fei,et al.Research on fire loads of college student dormitory in Yunnan[J].JOURNAL OF SAFETY SCIENCE AND TECHNOLOGY,2012,8(12):133.
[4]李英辉,张倩,李永刚.某大型商业建筑火灾危险性评估[J].中国安全生产科学技术,2009,5(2):117.
 LI Ying hui,ZHANG Qian,LI Yong gang.Fire risk assessment in a large shopping building[J].JOURNAL OF SAFETY SCIENCE AND TECHNOLOGY,2009,5(12):117.

备注/Memo

备注/Memo:
-
更新日期/Last Update: 2013-12-30