|本期目录/Table of Contents|

[1]蒋仲安,宋洋洋,丁〓伟,等.平煤八矿丁一风井通风阻力测定与结果分析[J].中国安全生产科学技术,2012,8(9):11.
 JIANG Zhong an,SONG Yang yang,DING Wei,et al.Resistance measure and analysis on dingyi ventilating shaft in Pingdingshan group 8th mine[J].JOURNAL OF SAFETY SCIENCE AND TECHNOLOGY,2012,8(9):11.
点击复制

平煤八矿丁一风井通风阻力测定与结果分析
分享到:

《中国安全生产科学技术》[ISSN:1673-193X/CN:11-5335/TB]

卷:
8
期数:
2012年9期
页码:
11
栏目:
学术论著
出版日期:
2012-09-30

文章信息/Info

Title:
Resistance measure and analysis on dingyi ventilating shaft  in Pingdingshan group 8th mine
作者:
蒋仲安1宋洋洋1丁〓伟1张海庆2焦向东2
(1 北京科技大学 土木与环境工程学院, 北京 100083) (2 平顶山天安煤业股份有限公司八矿, 平顶山 467012)
Author(s):
JIANG Zhongan1SONG Yangyang1DING Wei1ZHANG Haiqing2JIAO Xiangdong2
(1 School of Civil and Environment Engineering, University of Science & Technology Beijing, Beijing 100083, China) (2 The Eighth Coal Mine of Pingdingshan Tianan Coal Limited Liability Company, Pingdingshan 467012, China)
关键词:
丁一风井阻力测定阻力分布总阻力结果分析
Keywords:
dingyi ventilation shaft resistance measuring resistance distribution total resistance result analysis
分类号:
X936;TD724
DOI:
-
文献标志码:
A
摘要:
以平煤八矿丁一风井所服务的三个采区为例,系统地介绍了通风阻力测定方法、测定路线选择及测点布置。运用条件平差方法对测量数据进行处理,通过理论公式计算得到测定结果,然后对矿井通风系统进行分析。测定结果得出丁一风井通风系统的进风段、用风段和回风段阻力分布不平衡,部分区段通风阻力过大,通风总阻力超出了规定要求。结合丁一风井实际情况进行分析,找出了造成部分区段通风阻力过大的原因,并提出改进措施,为矿井通风安全管理提供了真实可靠的基础资料。
Abstract:
Taking the three mining areas of dingyi ventilating shaft in Pingdingshan 8th mine for example, the measuring method, measuring mute determination and measuring point distribution for ventilation resistance were systematically introduced. Condition adjustment method was used to handle the measurement data, and measuring results were got by theoretical formula calculation, then the mine ventilation system was analyzed. The resistance distribution of into wind period ,use wind period and return wind period of the ventilation system in dingyi ventilation shaft was not in balance based on the measuring results, the ventilation resistance of some sections were too large, the total ventilation resistance was beyond the regulation. The analysis was conducted combined with the actual situation of dingyi ventilating shaft, the reasons which cause ventilation resistance of some sections were too large were found out, and some improvement measures were put forward , which provides reliable base material for ventilation safety management in mine.