|本期目录/Table of Contents|

[1]郝永梅,邢志祥,邵辉,等.压力管道泄漏声发射源定位的实验研究[J].中国安全生产科学技术,2011,7(6):140-144.
 HAO Yong-mei,XING Zhi-xiang,SHAO Hui,et al.Experiment research on acoustic emission source location of leakage of pressure pipelines[J].JOURNAL OF SAFETY SCIENCE AND TECHNOLOGY,2011,7(6):140-144.
点击复制

压力管道泄漏声发射源定位的实验研究()
分享到:

《中国安全生产科学技术》[ISSN:1673-193X/CN:11-5335/TB]

卷:
7
期数:
2011年6期
页码:
140-144
栏目:
职业安全卫生管理与技术
出版日期:
2011-06-30

文章信息/Info

Title:
Experiment research on acoustic emission source location of leakage of pressure pipelines
文章编号:
1673-193X(2011)-06-0140-05
作者:
郝永梅邢志祥邵辉王凯全王小佳
常州大学环境与安全工程学院,常州? 213164
Author(s):
HAO Yong-mei XING Zhi-xiang SHAO Hui WANG Kai-quan WANG Xiao-jia
School of Environmental and Safety Engineering, Changzhou University, Changzhou? 213164, China
关键词:
管道泄漏声发射检测源定位互相关
Keywords:
pressure pipelines leakage AE testing source location Cross-correlation
分类号:
X933
DOI:
-
文献标志码:
A
摘要:
结合实验室声发射仪和油气管道设备,建立了充气管道泄漏声发射检测系统模型,分别在传感器间距、管道压力和泄漏量三种变化状态下进行了泄漏源定位影响实验。对管道泄漏声发射信号的时域统计特征、频域分布特征以及泄漏信号的相关性作了分析;从声信号能量累计和衰减特性方面对互相关定位法和幅度衰减测量区域定位法的可行性进行了计算,表明在传感器间距较小和泄漏量较小的状态下,在背景噪声较小的环境中,用互相关法具有较好的定位精度;而幅度衰减测量区域定位方法对泄漏源的定位误差较大。
Abstract:
Combined with Acoustic Emission(AE) equipment and Oil and Gas Pipeline in the laboratory, a model of AE pressure pipe testing was designed and set up. The source location experiments of leakage of pressure pipelines were did under three different state, as chang the distance between sensors, the pressure of pipelines and the leakage of pipeline by this system. Tested and verified the feasibilility of attenuation measurement of regional positioning method and correlation positioning method from attenuation characteristics of acoustic signals and energy accumulation two sides which was accorded to sound pressure correspond exponential decay law when signal is spreaded.The results show that correlation positioning method can do AE Location of leakage points of pressure pipelines effectively when the distance of sensor is little and the leakage is small, and there are some deviations by attenuation measurement of regional positioning method when pressure is changing.

参考文献/References:

[1] Guang Dai. AE testing in china[J].Non-destructive testing,2008,30(7):389-396. 戴光.声发射检测在中国[J].无损检测,2008,30(7):389-396.[2] Jingping Jiao,Yong Li and Cunfu He ,etc. Study on AE testing for pressure pipeline leak[J]. Journal of Beijing Polytechnic University,2003,29(2):144-166. 焦敬品,李涌,何存富,等.压力管道泄漏的声发射检测研究[J].北京工业大学学报,2003,29(2):144-166.[3] Jingping Jiao, Cunfu He and Bing Wu,etc. The progress in AE testing techniques for pipeline leak [J]. Non-destructive testing,2003,25(10):519-523. 焦敬品,何存富,吴斌等.管道声发射泄漏检测技术进展[J].无损检测,2003,25(10):519-523.[4] Gongtian Shen,Rongsheng Geng and Shifeng Liu ,etc. Acoustic emission source location technique[J].Non-destructive testing,2002,24(3):114-117. 沈功田,耿荣生,刘时风,等.声发射源定位技术[J].无损检测,2002,24(3):114-117.[5] R .K .Miller, etc.A reference for the development of acoustic emission pipeline leak detection techniques[J]. NDT&E,1999,32(1):1-8[6] Jiao Jingpin,He Cunfu,Wu Bin et al. App lication of wavelet transform on modal acoustic emission source location in thin plates with one sensor[J]. International Journal of Pressure Vessels & Pip ing, 2004, 81(5):427-431.[7] Gongtian Shen,Qingru Duan and Yufeng Zhou,etc. Study on artificial neural network detection modal AE signal of Pressure Vessels[J].Non-destructive testing,2001,23(4):144-146. 沈功田,段庆儒,周裕峰等.压力容器声发射信号人工神经网络模式识别方法的研究[J].无损检测,2001,23(4):144-146.[8] Efstratios M. Lympertos,Evangelos S. Dermatas. Acoustic emission source location in dispersive media[J]. Signal Processing 87 (2007) :3218–3225.[9]Zhenming Yuan,Yukuan Ma and Zheyun He,etc. AE techniques and application[M].Beijing: Press of machine industry,1985.袁振明,马羽宽,何泽云,等.声发射技术及其应用[M].北京:机械工业出版社,1985.[10] Mingwei Yang.AE testing[M]. Beijing: Press of machine industry,2005.杨明纬.声发射检测[M].北京:机械工业出版社,2005.[11] Gongtian Shen,Rongsheng Geng and Shifeng Liu ,etc. Source location of continuous acoustic emission signal [J].Non-destructive testing,2002,24(3):114-117.沈功田,耿荣生,刘时风,等.连续的声发射信号的源定位技术[J].无损检测,2002,24(4):164-167.[12] Shuli Shi.The measure method of AE source locating[J]. Journal of Liaoning University:natural science,1998,25(1):42-46.时书丽.声发射源定位的测试方法[J].辽宁大学学报:自然科学版,1998,25(1):42-46.

相似文献/References:

[1]邹兵,贾招弟,李伟.气体管道中阀门内漏声发射信号特性研究[J].中国安全生产科学技术,2015,11(7):30.[doi:10.11731/j.issn.1673-193x.2015.07.005]
 ZOU Bing,JIA Zhao-di,LI Wei.Study on characteristics of acoustic emission signal for internal leakage of valves in gas pipeline[J].JOURNAL OF SAFETY SCIENCE AND TECHNOLOGY,2015,11(6):30.[doi:10.11731/j.issn.1673-193x.2015.07.005]
[2]朱一龙,邢志祥,郝永梅,等.基于IEEMD样本熵分析的管道泄漏定位[J].中国安全生产科学技术,2019,15(12):17.[doi:10.11731/j.issn.1673-193x.2019.12.003]
 ZHU Yilong,XING Zhixiang,HAO Yongmei,et al.Localization of pipeline leakage based on IEEMD sample entropy analysis[J].JOURNAL OF SAFETY SCIENCE AND TECHNOLOGY,2019,15(6):17.[doi:10.11731/j.issn.1673-193x.2019.12.003]
[3]张逸斌,张浪,张慧杰,等.基于稳态模型的井下抽采主管道泄漏检测方法研究*[J].中国安全生产科学技术,2020,16(9):64.[doi:10.11731/j.issn.1673-193x.2020.09.010]
 ZHANG Yibin,ZHANG Lang,ZHANG Huijie,et al.Research on leakage detection method of underground extraction main pipeline based on steadystate model[J].JOURNAL OF SAFETY SCIENCE AND TECHNOLOGY,2020,16(6):64.[doi:10.11731/j.issn.1673-193x.2020.09.010]
[4]雷鹏,陈长坤,史聪灵,等.管廊内泄漏口朝向对天然气管道泄漏扩散影响的模拟分析*[J].中国安全生产科学技术,2021,17(10):133.[doi:10.11731/j.issn.1673-193x.2021.10.020]
 LEI Peng,CHEN Changkun,SHI Congling,et al.Simulation analysis on influence of leakage opening orientation in utility tunnel on leakage and diffusion of natural gas pipeline[J].JOURNAL OF SAFETY SCIENCE AND TECHNOLOGY,2021,17(6):133.[doi:10.11731/j.issn.1673-193x.2021.10.020]

备注/Memo

备注/Memo:
收稿日期:2011-01-09
作者简介:郝永梅,高级工程师。
基金项目:江苏省科技支撑计划(编号:BE2009624)和江苏省城市与工业安全重点实验室开放课题资助(编号:2008UIS004)
更新日期/Last Update: