[1]胡载彬.天然气长输管道安全运行监管研究 [D].上海:华东师范大学,2020.
[2]YU W C,SONG S F,LI Y C,et al.Gas supply reliability assessment of natural gas transmission pipeline systems [J].Energy,2018,162:853-870.
[3]KOYAMA H,WTANABE K,HIMMELBLAU D M.Identification of partial plugging in a gas-transport pipeline by an acoustic method [J].Applied Acoustic,1993,40(1):1-19.
[4]陈宝忠,王克勇,了启敏,等.管道中流体冻结位置的快速检测方法 [J].管道技术与设备,2002(6):40-41.
CHEN Baozhong,WANG Keyong,LIAO Qimin,et al.Detection method for freezing position of fluid in pipelines [J].Pipeline Technique and Equipment,2002(6):40-41.
[5]QU Z G,WANG H Y,AN Y,et al.Online monitoring method of hydrate agglomeration in natural gas pipelines based on acoustic active excitation [J].Measurement,2016,92:11-18.
[6]DUAN H F,LEE P J,GHIDOAUI M,et al.Transient wave-blockage interaction and extended blockage detection in elastic water pipelines [J].Journal of Fluids and Structures,2014,46:2-16.
[7]SHI W Y,YAO Y D,CHENG S Q,et al.Pressure transient analysis of fracturing stimulated well in multilayered fractured carbonate reservoirs:a field case in Western Sichuan Basin,China [J].Journal of Petroleum Science and Engineering,2019,184:106462.
[8]DUAN H F,LEE P J.Transient-based frequency domain method for dead-end side branch detection in reservoir pipeline-valve systems [J].Journal of Hydraulic Engineering,2016,142(2):04015042.
[9]MENICONI S,BRUNONE B,FERRANTE M.Water-hammer pressure waves interaction at cross-section changes in series in viscoelastic pipes [J].Journal of Fluids and Structures,2012,33:44-58.
[10]ADEWUMI M,ELTOHAMIE E,SOLAJA A.Possible detection of multiple blockages using transients [J].Journal of Energy Resource Technology,2003,125:154-159.
[11]ADELEKE N,ITYOKUMBUL M T,ADEMUMI M.Blockage detection and characterization in natural gas pipelines by transient pressure-wave reflection analysis [J].SPE Journal,2013,18:355-365.
[12]张红兵.长距离输气管道系统事故诊断技术研究[D].成都:西南石油学院,2015.
[13]刘恩斌,李长俊,彭善碧,等.基于压力波法的管道堵塞检测技术[J].天然气工业,2006,26 (4):112-114.
LIU Enbin,LI Changjun,PENG Shanbi,et al.Detection technology for pipeline plugging based on barotropic wave method [J].Natural Gas Industry,2006,26 (4):112-114.
[14]CHU J W,LIU Y,SONG Y C,et al.Experimental platform for blockage detection and investigation using propagation of pressure pulse waves in a pipeline [J].Measurement,2020,160:107877.
[15]CHU J W,YANG L,LIU Y,et al.Pressure pulse wave attenuation model coupling waveform distortion and viscous dissipation for blockage detection in pipeline [J].Energy Science Engineering,2019,8(1):260-265.