|本期目录/Table of Contents|

[1]李丹辰,钟茂华,梅棋,等.地铁同站台高架换乘车站火灾人员疏散研究[J].中国安全生产科学技术,2019,15(6):5-11.[doi:10.11731/j.issn.1673-193x.2019.06.001]
 LI Danchen,ZHONG Maohua,MEI Qi,et al.Study on personnel evacuation of fire in oneplatform interchange elevated metro station[J].JOURNAL OF SAFETY SCIENCE AND TECHNOLOGY,2019,15(6):5-11.[doi:10.11731/j.issn.1673-193x.2019.06.001]
点击复制

地铁同站台高架换乘车站火灾人员疏散研究
分享到:

《中国安全生产科学技术》[ISSN:1673-193X/CN:11-5335/TB]

卷:
15
期数:
2019年6期
页码:
5-11
栏目:
学术论著
出版日期:
2019-06-30

文章信息/Info

Title:
Study on personnel evacuation of fire in oneplatform interchange elevated metro station
文章编号:
1673-193X(2019)-06-0005-07
作者:
李丹辰1钟茂华1梅棋2刘畅3肖衍2
(1.清华大学 工程物理系 公共安全研究院,北京 100084;
2.北京市轨道交通设计研究院有限公司,北京 100068;
3.东北大学 资源与土木工程学院,辽宁 沈阳 110819)
Author(s):
LI Danchen1 ZHONG Maohua1 MEI Qi2 LIU Chang3 XIAO Yan2
(1. Institute of Public Safety Research, Department of Engineering Physics, Tsinghua University, Beijing 100084, China;
2. Beijing Rail and Transit Design & Research Institute CO., LTD., Beijing 100068, China;
3. College of Resources and Civil Engineering, Northeastern University, Shenyang Liaoning 110819, China)
关键词:
高架车站同站台换乘火灾疏散模拟
Keywords:
elevated station oneplatform interchange fire evacuation simulation
分类号:
X932
DOI:
10.11731/j.issn.1673-193x.2019.06.001
文献标志码:
A
摘要:
为研究地铁同站台高架换乘车站发生火灾事故的疏散模式,以具有该换乘形式的某实体车站的全尺寸火灾实验烟气扩散规律为基础,使用buildingEXODUS软件研究该车站站厅、站台、设备区、停靠列车等多个区域火灾场景下乘客疏散所需的时间。对比分析站厅中部闸机、站厅楼扶梯入口及站厅出入口附近3处发生火灾的场景,分别研究地铁车站内闸机及栅栏门、自动扶梯、应急出口等设施的运行状态对于疏散结果的影响,获取每种工况下的疏散时间,3种火灾场景下,上行扶梯关闭、所有闸机及栅栏门打开、应急出口打开能够有效减少疏散时间,火源位于楼扶梯入口时对疏散时间的影响最大;研究站台中部、站台楼扶梯入口2处发生火灾的场景下,扶梯运行状态对于疏散时间的影响,上行扶梯停止运行后的乘客疏散时间相较于扶梯上行时分别降低41%,35%;分析设备区火灾对于设备区内工作人员疏散时间与乘客疏散时间的影响,由于工作人员数量相对较少,对车站整体疏散时间影响不明显;对比分析4B编组列车车头、车中及车尾发生火灾的场景对于乘客疏散时间的影响,火源位于车中时对疏散时间的影响最大。
Abstract:
To study the evacuation patterns in the oneplatform interchange elevated metro station under fire accident, based on the smoke diffusion laws of fullscale fire experiments in an actual station with this interchange form, the required evacuation time of passengers in the fire scenes of multiple areas such as hall, platform, equipment area and stopping train in this station were studied by using the buildingEXODUS software. The fire scenes around the middle gate, stairs and escalators entrances and exits of hall in the metro station were compared and analyzed, then the influence of running status of gates and fences, escalators, emergency exits and other facilities in the metro station on the evacuation results were studied respectively, and the evacuation time under each working condition were obtained. The results showed that in three fire scenes, closing the upescalators, opening all the gates and fences, and opening the emergency exits would reduce the evacuation time effectively, and when the fire source was located at the stairs and escalators entrances, the influence on the evacuation time was the greatest. The influence of running status of escalators on the evacuation time in the fire scenes at the middle part and the stairs and escalators entrances of platform was studied, it showed that the passengers evacuation time when the upescalators stopped running reduced by 41% and 35% respectively compared with that when the escalators kept running. The influence of fire in the equipment area on the evacuation time of staff in the equipment area and passengers was analyzed, it showed that the influence on the overall evacuation time of station was not obvious because the quantity of staff was relatively less. The influence of fire scenes at the head stock, middle part and tail of 4B marshaling train on the evacuation time of passengers were compared and analyzed, it showed that the influence on the evacuation time was the greatest when the fire source was located at the middle part of train.

参考文献/References:

[1]钟茂华, 史聪灵, 涂旭炜,等. 深埋岛式地铁车站突发事件时人员疏散模拟研究[J]. 中国安全科学学报, 2007, 17(8):20-25. ZHONG Maohua, SHI Congling, TU Xuwei, et al.Simulation study on human evacuation during emergency in deeply buried-inland metro station[J]. China Safety Science Journal, 2007, 17(8):20-25.
[2]陈涛,翁文国,杨锐,等. 人群疏散模拟分析技术在应急体系中的应用[J]. 应用基础与工程科学学报,2006,14(S):172-178. CHEN Tao, WENG Wenguo, YANG Rui, et al. Crowd evacuation modeling study and its application in emergency response system[J]. Journal of Basic Science and Engineering, 2006,14(S):172-178.
[3]何利英. 中庭式地铁车站火灾安全疏散仿真研究[J]. 地下空间与工程学报, 2010, 6(4):861-866. HE Liying. Evacuation simulation of atrium metro station in fire accidents[J]. Chinese Journal of Underground Space and Engineering, 2010, 6(4):861-866.
[4]SHI C, ZHONG M, NONG X, et al. Modeling and safety strategy of passenger evacuation in a metro station in China[J]. Safety Science, 2012, 50(5):1319-1332.
[5]李意. 地铁车站火灾条件下疏散客流状态的仿真分析[D].成都:西南交通大学, 2017.
[6]王志刚, 郭建平, 赵越. 亦庄线高架车站安全疏散设计[J]. 市政技术, 2010,28(S2):49-51. WANG Zhigang,GUO Jianping,ZHAO Yue.Evacuation design for elevated station of Yizhuang line project[J]. Municipal Engineering Technology, 2010,28(S2):49-51.
[7]史聪灵, 钟茂华, 刘智成, 等. 地铁高架车站火灾时人员疏散的性能化设计[J]. 中国安全生产科学技术, 2007, 3(4):11-15. SHI Congling,ZHONG Maohua,LIU Zhicheng, et al.Performance-based design on occupant evacuation of elevated metro station in fires[J].Journal of Safety Science and Technology, 2007, 3(4):11-15.
[8]齐茂利. 基于微观仿真的同站台换乘站客流疏散研究[D].北京:北京交通大学, 2009.
[9]张洪娟. 基于火灾烟气数值模拟的地铁旅客安全疏散研究[D].南京:东南大学, 2015.
[10]刘梦洁. 基于FDS和Pathfinder的地铁车站火灾疏散研究[D]. 武汉:华中科技大学, 2016.
[11]钟茂华, 刘畅, 田向亮,等. 地铁同站台高架换乘车站火灾全尺寸实验研究-(1)火灾场景设计[J]. 中国安全生产科学技术, 2018, 14(3):27-33. ZHONG Maohua, LIU Chang,TIAN Xiangliang, et al.Full-scale fire experimental study on the one-platform-interchange elevated metro station-(1) design of fire scenario[J]. Journal of Safety Science and Technology, 2018, 14(3):27-33.
[12]钟茂华, 刘畅, 田向亮, 等. 地铁同站台高架换乘车站火灾全尺寸实验研究-(2)站厅火灾[J]. 中国安全生产科学技术, 2018, 14(4):5-12. ZHONG Maohua, LIU Chang, TIAN Xiangliang, et al. Full-scale fire experimental study on the one-platform-interchange elevated metro station-(1) station hall fire[J]. Journal of Safety Science and Technology, 2018, 14(4):5-12.
[13]钟茂华, 肖衍, 胡家鹏, 等. 地铁同站台高架换乘车站火灾全尺寸实验研究-(3)站台火灾[J]. 中国安全生产科学技术, 2018,14 (6):14-20. ZHONG Maohua,XIAO Yan, HU Jiapeng, et al. Full-scale fire experimental study on the one-platform-interchange elevated metro station-(3) platform fire[J]. Journal of Safety Science and Technology, 2018,14 (6):14-20.
[14]钟茂华, 刘畅, 田向亮, 等. 地铁同站台高架换乘车站火灾全尺寸实验研究-(4)设备区火灾[J]. 中国安全生产科学技术, 2018,14 (7):18-25. ZHONG Maohua, LIU Chang, TIAN Xiangliang, et al.Full-scale fire experimental study on the one-platform-interchange elevated metro station-(4) equipment area fire[J]. Journal of Safety Science and Technology, 2018,14 (7):18-25.
[15]全国公共安全基础标准化技术委员会.地铁安全疏散规范:GB/T 33668-2017[S].北京:中国标准出版社,2017.
[16]北京市规划委员会.地铁设计规范:GB 50157-2013[S].北京:中国建筑工业出版社,2014.

相似文献/References:

备注/Memo

备注/Memo:
收稿日期: 2019-03-29
* 基金项目: 国家重点研发计划项目(2016YFC0802500);国家自然科学基金项目(51425404,71790613)
作者简介: 李丹辰,硕士研究生,主要研究方向为地铁安全。
通信作者: 钟茂华,博士,研究员,主要研究方向为地铁安全。
更新日期/Last Update: 2019-07-09