|本期目录/Table of Contents|

[1]贠璞.大型原油商业储备油库火灾危险性数值模拟分析[J].中国安全生产科学技术,2013,9(12):179-184.[doi:10.11731/j.issn.1673-193x.2013.12.030]
 YUN Pu.Numerical simulation on fire hazard of large commercial crude oil reserve depot[J].JOURNAL OF SAFETY SCIENCE AND TECHNOLOGY,2013,9(12):179-184.[doi:10.11731/j.issn.1673-193x.2013.12.030]
点击复制

大型原油商业储备油库火灾危险性数值模拟分析
分享到:

《中国安全生产科学技术》[ISSN:1673-193X/CN:11-5335/TB]

卷:
9
期数:
2013年12期
页码:
179-184
栏目:
职业安全卫生管理与技术
出版日期:
2013-12-30

文章信息/Info

Title:
Numerical simulation on fire hazard of large commercial crude oil reserve depot
作者:
贠璞
(宁夏吴忠市红寺堡区消防大队,宁夏吴忠751900)
Author(s):
YUN Pu
(Hongsipu District Fire Brigade, Wuzhong Ningxia 751900, China)
关键词:
巨型储油罐火灾危险数值模拟消防安全分析
Keywords:
huge oil storage tank fire hazard numerical simulation fire protection safety analysis
分类号:
X936
DOI:
10.11731/j.issn.1673-193x.2013.12.030
文献标志码:
A
摘要:
石油储备油库多向大型化、复杂化方向发展,发生事故时扑救非常困难。为了深入探讨巨型油罐火灾发展趋势与规律、事故危害后果,结合宁夏惠安堡原油商业储备油库这一工程实例,采用基于大涡模拟的FDS模型作为模拟计算平台,对巨型油罐火灾的燃烧过程进行数值模拟计算。通过分析计算,得到烟气分布、温度分布、热辐射强度分布等火灾过程参数的变化趋势,以及在有风和无风状态下着火罐对相邻油罐的影响,探讨现行建设工程消防技术标准就储罐防火间距、火灾时对邻近罐体冷却设计要求运用于巨型储油罐时的消防安全状况,为巨型储油罐消防安全科学合理设计提供理论依据。
Abstract:
The crude oil reserve depot is tending to be large and complex, and the fire fighting is quite difficult. In order to deeply discuss the development trend, principles and consequence of fire accident for huge oil storage tank, combining with the practical engineering case of Huianpu commercial crude oil reserve depot in Ningxia, by applying FDS model based on large eddy simulation as calculation platform, the numerical simulation on combustion process of huge oil storage tank fire was performed. The change trends of fire process parameters, such as smoke distribution, temperature distribution and thermal radiation intensity, were obtained, as well as the influence of flaming tank on adjacent tanks under windy and windless〖JP2 conditions. The fire protection safety status when applying the design requirements in the existing technical standards on fire control of construction engineering, such as fire separation distance of tank and cooling adjacent tanks during fire process, on the huge oil storage tank was discussed, which can provide theoretical foundation to the scientific and reasonable design on fire protection safety of huge oil storage tank.〖JP

参考文献/References:

[1]中国原油进口依存度首超警戒线. http://jjckb.xinhuanet.com/gnyw/201003/29/content_214288htm
[2]陈久行.石油安全与石油储备[J].中国石油和化工经济分析,2007(14):4551 CHEN Jiuxing.The petroleum security and the petroleum stockpile [J]. Chinese Petroleum and Chemical Economic Analysis, 2007(14):4551
[3]苏国胜.李文波.郎需庆, 等.邦斯菲尔德油库事故的启示[J].安全、健康和环境,2006(12) SU Guosheng, LI Wenbo, LANG Xuqing, et al. Bunce fielder fuel depot accident enlightenment [J]. Security, Health and Environment, 2006(12) 
[4]中石油兰州石化爆炸“三问”. http://www.022net.com/2010/120/494971302294799html
[5]J.E.Floyd, K.B.McGrattan,S.Hostikka,et al,CFD Fire Simulation Using Mixture Fraction Combustion and Finite Volume Radiative Heat Transfer[J],Journal of Fire Protection Engineering,2003
[6]G.P. Fomey, K.B.McGrattan,User’S Guide for Smokeview Version3.1A Tool for Visualizing Fire Dynamics Simulation Data[R],NISTIR 6980,National Institute of Standards and Technology, USA,2003
[7]Nathaniel Mead Petterson, Assessing the Feasibility of Reducing the Grid Resolution in FDS Field Modelling [R], Fire Engineering Research Report,University of Canterbury,2002
[8]K.B.McGrattan, H.R.Baum, R.G. Rehm, et al, Fire Dynamics Simulator (Version 4)—Technical Reference Guide[R],NISTIR 6783,2003 Ed.,National Institute of Standards and Technology, USA,2003
[9]G.H. Lee, Distribution of heat and smoke related to openings in HiseRise apartment building fires. T. Korean Institute of Fire Sci. & Eng, 2001, 5979
[10]Gritzo, L.A., Nicolette, V.E, Tieszen, S.R., and Moya, J.L. "Heat Transfer to the Fuel Surface in Large Pool Fires," Transport Phenomenon in Combustion, S.H. Chan, ed,Taylor and Francis, 1996〖FL)〖HJ〖HT〖ST〖WT 〖LM

相似文献/References:

备注/Memo

备注/Memo:
-
更新日期/Last Update: 2013-12-30