[1]TSUKAHARA M, KOSHIBA Y, OHTANI H. Effectiveness of downward evacuation in a large-scale subway fire using fire dynamics simulator[J].Tunnelling and Underground Space Technology,2011(26):573-581.
[2]ROH J S , RYOU H S , PARK W H, et al. CFD simulation and assessment of life safety in a subway train fire[J].Tunnelling and Underground Space Technology,2009(24):447-453.
[3]孟娜. 地铁车站关键结合部位火灾烟气流动特性与控制模式优化研究[D].合肥:中国科学技术大学,2014.
[4]张茜,曹建华,王文倩. 典型地铁火灾场景中烟气蔓延与控制研究[J]. 中国安全生产科学技术, 2011, 7(7):20-25.ZHANG Qian,CAO Jianhua,WANG Wenqian. Study on smoke propagation and control of a typical fire scenario in the subway [J]. Journal of Safety Science and Technology, 2011, 7(7):20-25.
[5]何开远,樊洪明,赵耀华,等.岛式地铁站台火灾烟气运动的数值模拟[J].工程热物理学报. 2010, 31(2):317-320.HE Kaiyuan,FAN Hongming,ZHAO Yaohua,et al. Numerical simulation on smoke flow in subway with island-platform and side-platform [J]. Journal of Engineering Thermophysics, 2010, 31(2):317-320.
[6]陈静,方正,袁建平.基于空气幕的多层地铁车站站台火灾时的防排烟模式[J].武汉大学学报(工学版). 2017, 50(2):257-268.CHEN Jing,FANG Zheng,YUAN Jianping. Study of smoke control modes of platform fire in multilayer metro station based on air curtain [J]. Engineering Journal of Wuhan University. 2017, 50(2):257-268.
[7]石郎君,蒋军成,周汝,等. 高密度人员空间分布对地铁火灾烟气扩散的影响[J].南京工业大学学报(自然科学版),2017, 39(2): 57-63.SHI Langjun,JIANG Juncheng,ZHOU Ru,et al. Effects of the high-density spatial distribution of passengers on smoke diffusion in subway fire [J]. Journal of Nanjing Tech University(Natural Science Edition), 2017, 39(2): 57-63.
[8]张南燕,唐婕. 火源位置对大空间建筑火灾烟气蔓延影响研究[J]. 武警学院学报.2016, 32(2): 16-19.ZHANG Nanyan,TANG Jie. On the influence of fire source location on the smoke movement in a spacious building fire [J]. Journal of Chinese People’s Armed Police Force Academy, 2016, 32(2): 16-19.
[9]罗娜. 基于地铁交错车站的大空间建筑火灾防排烟技术研究[D].西安:西安建筑科技大学,2015.
[10]周志望,周妍静,王浩波.大空间建筑不同排烟系统作用下的烟气控制效果研究[J].火灾科学.2014, 23(3): 182-188.ZHOU Zhiwang,ZHOU Yanjing,WANG Haobo. Research on the effect of different smoke controlling methods in large space[J]. Fire Safety Science, 2014, 23(3): 182-188.
[11]颜艳,高平. 大空间建筑自然排烟有效性实体实验[J].消防科学与技术,2015, 34(12): 1583-1586.YAN Yan,GAO Ping. Entity experiment of validity of natural smoke exhaust in large building [J]. Fire Science and Technology, 2015, 34(12): 1583-1586.
[12]毛少华. 烟气中性面的理论模型及实验研究[D].合肥:中国科学技术大学,2012.
[13]刘方.中庭火灾烟气流动与烟气控制研究[D].重庆:重庆大学,2002.
[14]LI L M, CHENG X D, CUI Y, et al. Estimation of smoke arrival time in tunnel fires [J]. Tunnelling and Underground Space Technology, 2013 (38) : 431-434.
[15]HU L H,HUO R , LI Y Z, et al. Tracking a ceiling jet front for hot smoke tests in tunnels [J]. Journal of Fire Sciences,2007(25): 99-108.
[16]钟茂华,刘畅,田向亮,等. 地铁同站台高架换乘车站火灾全尺寸实验研究-(1)火灾场景设计[J]. 中国安全生产科学技术. 2018,14(3):10-14.ZHONG Maohua,LIU Chang,TIAN Xiangliang, et al. Full-scale experimental study on fire in one-platform-interchange elevated metro station-(1) design of fire scenario [J]. Journal of Safety Science and Technology, 2018,14(3):10-14.
[17]JI J, BI Y B, KONDAPALLI K, et al.. Influence of aspect ratio of tunnel on smoke temperature distribution under ceiling in near field of fire source [J]. Applied Thermal Engineering, 2016(106) : 1094-1102.
[18]HU L H, CHEN L F, TANG W, A global model on temperature profile of buoyant ceiling gas flow in a channel with combining mass and heat loss due to ceiling extraction and longitudinal forced air flow [J]. International Journal of Heat and Mass Transfer, 2014 (79): 885-892.
[19]LIU C, ZHONG M H, SHI C L, et al. Temperature profile of fire-induced smoke in node area of a full-scale mine shaft tunnel under natural ventilation [J].Applied Thermal Engineering, 2017(110):382-389.
[20]NFPA, NFPA92B Guide for Smoke Management Systems in Malls, Atria, and Large Areas[R].National Fire Protection Association, USA, 2009.
[21]ZHONG M H, SHI C L, HE L, et al. Smoke development in full-scale sloped long and large curved tunnel fires under natural ventilation [J]. Applied Thermal Engineering, 2016(108):857-865.
[22]OKA Y, IMAZEKI O.Temperature and velocity distributions of a ceiling jet along an inclined ceiling-Part 1: Approximation with exponential function [J].Fire Safety Journal, 2014(65):41-52.
[23]史聪灵,钟茂华,汪良旗,等. 地铁车站及隧道全尺寸火灾实验研究(2)-区间隧道火灾[J].中国安全生产科学技术. 2012, 8(8):28-34.SHI Congling,ZHONG Maohua,WANG Liangqi,et al. Investigation of full-scale burning experiments in metro station and tunnel (2)-interval tunnel fires [J]. Journal of Safety Science and Technology, 2012, 8(8):28-34.
[1]史聪灵.地铁换乘车站客流疏运模拟及风险分析(1)-T型车站[J].中国安全生产科学技术,2011,7(4):11.
SHI-Cong-ling.Simulation and risk analysis on passenger transportation of metro transfer station(1)-T-type station[J].JOURNAL OF SAFETY SCIENCE AND TECHNOLOGY,2011,7(6):11.
[2]邓军,王萌.地铁火灾监控技术发展的德尔菲预见性分析[J].中国安全生产科学技术,2011,7(5):77.
Deng Jun,?Wang Meng.Delphi technology foresight analysis on development of the metro fire monitoring system[J].JOURNAL OF SAFETY SCIENCE AND TECHNOLOGY,2011,7(6):77.
[3]王震,贺农农.西安地铁工程安全文化的建立[J].中国安全生产科学技术,2011,7(5):159.
WANG Zhen,HE Nong-nong.Establishment of safety culture in Xi’an metro engineering[J].JOURNAL OF SAFETY SCIENCE AND TECHNOLOGY,2011,7(6):159.
[4]史聪灵,钟茂华,张岚,等.地铁换乘车站客流疏运模拟及风险分析(2)——单通道换乘车站[J].中国安全生产科学技术,2011,7(8):21.
SHI Cong-ling,ZHONG Mao-hua,ZHANG Lan,et al.Simulation and risk Analysis on passenger transportation of metro transfer station(2)——Single passage transferring Station[J].JOURNAL OF SAFETY SCIENCE AND TECHNOLOGY,2011,7(6):21.
[5]马骏.扩孔型锚固技术在西安地铁工程中的应用[J].中国安全生产科学技术,2011,7(9):195.
MA Jun.Anchor hole enlargement technology in Xi’an Subway Project[J].JOURNAL OF SAFETY SCIENCE AND TECHNOLOGY,2011,7(6):195.
[6]刘新军.西安地铁穿越地裂缝带支护结构设计研究[J].中国安全生产科学技术,2012,8(2):144.
LIU Xin jun.Design of support structure of Xi’an metro through ground fissure[J].JOURNAL OF SAFETY SCIENCE AND TECHNOLOGY,2012,8(6):144.
[7]郭雩,何理,石杰红,等.地铁不同人群疏散行为特征调查问卷研究[J].中国安全生产科学技术,2012,8(4):183.
GUO Yu,HE Li,SHI Jie hong,et al.Questionnaire research on the evacuation behavior characteristics
of different crowds in subway[J].JOURNAL OF SAFETY SCIENCE AND TECHNOLOGY,2012,8(6):183.
[8]雷斌,曹振,张宁.西安地铁安全文化体系建设研究[J].中国安全生产科学技术,2012,8(6):221.
LEI Bin,CAO Zhen,ZANG Ning.Study on system constructions of safety culture in Xi’an metro[J].JOURNAL OF SAFETY SCIENCE AND TECHNOLOGY,2012,8(6):221.
[9]史聪灵,钟茂华,汪良旗,等.地铁车站及隧道全尺寸火灾实验研究(2)
——区间隧道火灾[J].中国安全生产科学技术,2012,8(8):28.
SHI Cong ling,ZHONG Mao hua,WANG Liang qi,et al.Investigation of fullscale burning experiments in metro station and tunnel (2)
-interval tunnel fires[J].JOURNAL OF SAFETY SCIENCE AND TECHNOLOGY,2012,8(6):28.
[10]王垚,冯超.地铁车站深基坑围护桩优化及其数值分析[J].中国安全生产科学技术,2013,9(2):54.
WAGN Yao,FENG Chao.Numerical analysis and optimization on supporting piles in deep
foundation fit of metro station[J].JOURNAL OF SAFETY SCIENCE AND TECHNOLOGY,2013,9(6):54.
[11]钟茂华,刘畅,田向亮,等.地铁同站台高架换乘车站火灾全尺寸实验研究-(1)火灾场景设计[J].中国安全生产科学技术,2018,14(3):27.[doi:10.11731/j.issn.1673-193x.2018.03.004]
ZHONG Maohua,LIU Chang,TIAN Xiangliang,et al.Full-scale experimental study on fire in one-platform-interchange elevated metro station-(1) design of fire scenario[J].JOURNAL OF SAFETY SCIENCE AND TECHNOLOGY,2018,14(6):27.[doi:10.11731/j.issn.1673-193x.2018.03.004]
[12]钟茂华,刘畅,田向亮,等.地铁同站台高架换乘车站火灾全尺寸实验研究—(2)站厅火灾[J].中国安全生产科学技术,2018,14(4):5.[doi:10.11731/j.issn.1673-193x.2018.04.001]
ZHONG Maohua,LIU Chang,TIAN Xiangliang,et al.Full-scale experimental study on fire in one-platform-interchange elevated metro station—(2) station hall fire[J].JOURNAL OF SAFETY SCIENCE AND TECHNOLOGY,2018,14(6):5.[doi:10.11731/j.issn.1673-193x.2018.04.001]
[13]钟茂华,刘畅,田向亮,等.地铁同站台高架换乘车站火灾全尺寸实验研究-(4)设备区火灾[J].中国安全生产科学技术,2018,14(7):18.[doi:10.11731/j.issn.1673-193x.2018.07.003]
ZHONG Maohua,LIU Chang,TIAN Xiangliang,et al.Full-scale experimental study on fire in one-platform-interchange elevated metro station—(4) equipment area fire[J].JOURNAL OF SAFETY SCIENCE AND TECHNOLOGY,2018,14(6):18.[doi:10.11731/j.issn.1673-193x.2018.07.003]