|本期目录/Table of Contents|

[1]王黎珣,魏利军,李晓云,等.基于CFD模拟的带压火焰射流辐射热阻断效果评估*[J].中国安全生产科学技术,2024,20(9):134-140.[doi:10.11731/j.issn.1673-193x.2024.09.016]
 WANG Lixun,WEI Lijun,LI Xiaoyun,et al.Evaluation on heat blocking effect of jet radiation by pressurized flame based on CFD simulation[J].JOURNAL OF SAFETY SCIENCE AND TECHNOLOGY,2024,20(9):134-140.[doi:10.11731/j.issn.1673-193x.2024.09.016]
点击复制

基于CFD模拟的带压火焰射流辐射热阻断效果评估*
分享到:

《中国安全生产科学技术》[ISSN:1673-193X/CN:11-5335/TB]

卷:
20
期数:
2024年9期
页码:
134-140
栏目:
职业安全卫生管理与技术
出版日期:
2024-09-30

文章信息/Info

Title:
Evaluation on heat blocking effect of jet radiation by pressurized flame based on CFD simulation
文章编号:
1673-193X(2024)-09-0134-07
作者:
王黎珣魏利军李晓云栾婷婷多英全王如君
(1.中国矿业大学(北京) 应急管理与安全工程学院,北京 100083;
2.中国安全生产科学研究院,北京 100012;
3.重大危险源与化工园区系统安全应急管理部重点实验室,北京 100012;
4.北京石油化工学院 安全工程学院,北京 102617)
Author(s):
WANG Lixun WEI Lijun LI Xiaoyun LUAN Tingting DUO Yingquan WANG Rujun
(1.School of Emergency Management and Safety Engineering,China University of Mining and Technology-Beijing,Beijing 100083,China;
2.China Academy of Safety Science and Technology,Beijing 100012,China;
3.Key Laboratory of Major Hazard Installations and Chemical Industry Park System Safety,MEM,Beijing 100012,China;
4.School of Safety Engineering,Beijing Institute of Petrochemical Technology,Beijing 102617,China)
关键词:
防火墙带压火焰热阻断效果CFD模拟个人风险
Keywords:
firewall pressurized flame heat blocking effect CFD simulation individual risk
分类号:
X937;X932
DOI:
10.11731/j.issn.1673-193x.2024.09.016
文献标志码:
A
摘要:
为评估防火墙作为安全屏障对带压火焰射流辐射热的阻断效果,结合CFD模拟和个人风险计算建立热阻断效果定量评估方法。以某化工企业乙烯反应塔泄漏产生的带压火焰为研究对象,利用FLACS软件模拟得到对于储罐表面受到热辐射影响相对最大的位置处(观测点1)原始场景和增加防火墙后,带压火焰作用于邻近储罐的热辐射强度,并计算多米诺效应概率和个人风险值。研究结果表明:原始场景下该位置热辐射强度为310.69 kW/m2,事故会扩展到邻近储罐,并产生多米诺效应,多米诺效应概率为7.14×10-6;增加防火墙后该位置热辐射强度降低为24.69 kW/m2,约为原始场景热辐射的1/13,此时无多米诺效应产生;原始场景下个人风险值为2.11×10-9,增加防火墙后为6.33×10-13,减小4个数量级,表明防火墙对带压火焰射流辐射的热阻断效果显著。研究结果可为化工企业安全策略构建提供一定理论参考。
Abstract:
In order to evaluate the heat blocking effect of firewall as a safety barrier on the jet radiant of pressurized flame,a quantitative evaluation method of heat blocking effect was established by combining CFD simulation and individual risk calculation.Taking the pressurized flame generated by the leakage of ethylene reaction tower in a chemical enterprise as the research object,the thermal radiation intensity of pressurized flame acting on the adjacent storage tank in the original scene and adding the firewall were simulated by FLACS software,and the probability of domino effect and individual risk were calculated.The results show that for the location where the surface of storage tank is relatively most affected by thermal radiation (observation point 1),the thermal radiation intensity in the original scene is 310.69 kW/m2,and the accident will spread to the neighboring tank and produce a domino effect,with the probability of domino effect as 7.14×10-6.After the firewall is added,the thermal radiation intensity decreases to 24.69 kW/m2,which is about 1/13 of that in original scene,and no domino effect occurs at this time.In the original scenario,the personal risk is 2.11×10-9,and 6.33×10-13 after adding the firewall,which is reduced by 4 orders of magnitude,indicating that the thermal blocking effect of firewall on the jet radiation of pressurized flame is significant.The research results can provide some theoretical reference for the construction of safety strategies in chemical enterprises.

参考文献/References:

[1]万婧,容振乾,赵远飞,等.2010—2019年我国化工行业较大以上生产安全事故统计分析及启示[J].工业安全与环保,2021,47(5):59-63. WAN Jing,RONG Zhenqian,ZHAO Yuanfei,et al.Statistical analysis and lessons of major production safety accidents in chemical industry of China from 2010 to 2019[J].Industrial Safety and Environmental Protection,2021,47(5):59-63.
[2]吉安琪.石油化工场所喷射火灾数值模拟研究[D].抚顺:辽宁石油化工大学,2021.
[3]石军花,朱梅,李进,等.化工园区储罐火灾热辐射模型仿真研究[J].中国安全科学学报,2022,32(增刊1):79-83. SHI Junhua,ZHU Mei,LI Jin,et al.Simulation study on thermal radiation model of storage tank fire in chemical industry[J].China Safety Science Journal,2022,32(Supplement 1):79-83.
[4]周宁,吴露露,李雪,等.池火灾环境中石化管廊管道失效的规律[J].南京工业大学学报(自然科学版),2021,43(2):150-158,196. ZHOU Ning,WU Lulu,LI Xue,et al.Failure law of petrochemical pipe rack under pool fire[J].Journal of Nanjing University of Technology (Natural Science Edition),2021,43(2):150-158,196.
[5]邱健.储罐池火灾安全屏障性能评估及其应用研究[D].北京:北京化工大学,2021.
[6]SKLET S.Safety barriers:definition,classification,and performance[J].Journal of Loss Prevention in the Process Industries,2006,19(5):494-506.
[7]徐安琦,钱一潇,钱瑜.化工企业多米诺事故安全屏障优化布置[J].中国安全科学学报,2018,28(2):175-180. XU Anqi,QIAN Yixiao,QIAN Yu.Study on optimal layout of barriers against domino effects in chemical enterprise[J].China Safety Science Journal,2018,28(2):175-180.
[8]伍壮,侯磊,伍星光,等.安全防护对原油罐区多米诺火灾事故发生概率的影响[J].安全与环境工程,2020,27(1):166-172. WU Zhuang,HOU Lei,WU Xingguang,et al.The influence of safety protection on the probability of domino accident in tank area[J].Safety and Environmental Engineering,2020,27(1):166-172.
[9]吴守志,侯磊,伍星光,等.安全屏障对储油罐区池火灾多米诺效应概率的影响[J].油气储运,2022,41(2):165-176. WU Shouzhi,HOU Lei,WU Xingguang,et al.Influence of safety barriers on probability of domino effect triggerred by pool fire in tank farm[J].Oil & Gas Storage and Transportation,2022,41(2):165-176.
[10]张金伟,许颖,李栋梁,等.基于BIM-CFD的变压器防火墙火灾性能化设计[J].北京交通大学学报,2021,45(3):84-92. ZHANG Jinwei,XU Ying,LI Dongliang,et al.Fire performance design of transformer firewall based on BIM and CFD[J].Journal of Beijing Jiaotong University,2021,45(3):84-92.
[11]罗业雄.变电站装配式主变防火墙的设计与实践[J].科技与创新,2018(14):133-134.
[12]杨灿.原油库区泄漏与火灾风险场景集成风险分析[D].青岛:中国石油大学(华东),2023.
[13]BAI Y P,WU J S,SUN Y X,et al.BN & CFD-based quantitative risk assessment of the natural gas explosion in utility tunnels[J].Journal of Loss Prevention in the Process Industries,2022,80:104883.
[14]刘迪,党文义,王溪舸,等.油氢合建站典型泄漏火灾热辐射后果模拟分析[J].消防科学与技术,2021,40(6):851-854. LIU Di,DANG Wenyi,WANG Xige,et al.Simulation analysis of thermal radiation consequences of typical leakage fire in oil and hydrogen refueling station[J].Fire Science and Technology,2021,40(6):851-854.
[15]周亚薇,匡卓伦,冷雪,等.天然气管道全管径断裂喷射火对周边建筑物外立面热辐射分布研究[J].安全与环境学报,2023,23(8):2668-2674. ZHOU Yawei,KUANG Zhuolun,LENG Xue,et al.Research on the thermal radiation distribution of full bore rupture jet fire from natural gas pipeline on the surrounding building facades[J].Journal of Safety and Environment,2023,23(8):2668-2674.
[16]COZZANI V,GUBINELLI G,SALZANO E.Escalation thresholds in the assessment of domino accidental events[J].Journal of Hazardous Materials,2006,129(1-3):1-21.
[17]COZZANI V,ANTONIONI G,SPADONI G.Quantitative assessment of domino scenarios by a GIS-based software tool[J].Journal of Loss Prevention in the Process Industries,2006,19(5):463-477.
[18]中国石油化工股份有限公司青岛安全工程研究院.石化装置定量风险评估指南[M].北京:中国石化出版社,2007.
[19]秦宇毅,吕品,周朱晟,等.基于LPG储罐事故演化系统的个人风险分析[J].消防科学与技术,2023,42(5):615-621. QIN Yuyi,LYU Pin,ZHOU Zhusheng,et al.Multi-scenario accident individual risk analysis based on LPG tank accident evolution system[J].Fire Science and Technology,2023,42(5):615-621.

相似文献/References:

备注/Memo

备注/Memo:
收稿日期: 2023-12-26
* 基金项目: “十四五”国家重点研发计划项目(2021YFC3001201)
作者简介: 王黎珣,硕士研究生,主要研究方向为定量风险评估、三维事故后果模拟、可靠性研究等。
通信作者: 魏利军,博士,教授级高级工程师,主要研究方向为重大工业事故预防与控制、重大危险源辨识评价与控制、定量风险与韧性评估、安全规划和应急管理。
更新日期/Last Update: 2024-10-08